ABB GJL121 Contactor, 110V ac, 127 V ac Coil, 3-Pole, 20 A, 4 kW 110V ac, 127 V ac, 3 NO/1 NC, 690V
- RS 제품 번호:
- 253-4732
- 제조사 부품 번호:
- GJL1211009R8014
- 제조업체:
- ABB
Subtotal (1 pack of 10 units)*
₩1,580,300.00
제조사가 재고 비축중
- 2026년 8월 24일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 | 한팩당* |
|---|---|---|
| 10 + | ₩158,030.00 | ₩1,580,300.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 253-4732
- 제조사 부품 번호:
- GJL1211009R8014
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Coil Voltage | 110, 127V ac | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Series | GJL121 | |
| Power Rating | 4kW | |
| Function | Control Unit | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 3 NO/1 NC | |
| Auxiliary Contact Configuration | 1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Soldering | |
| Minimum Operating Temperature | -25°C | |
| Operational Current Ie | 12A | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 110, 127V ac | |
| Maximum Operating Temperature | 55°C | |
| Width | 47.5mm | |
| Length | 47.7mm | |
| Depth | 47.7mm | |
| Standards/Approvals | UL 60947-4-1, IEC/EN 60947-5-1, IEC/EN 60947-4-1, IEC/EN 60947-1, UL 60947-1 | |
| Pole and Throw Configuration | 3P | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Coil Voltage 110, 127V ac | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Series GJL121 | ||
Power Rating 4kW | ||
Function Control Unit | ||
Mount Type DIN Rail | ||
Normal State Configuration 3 NO/1 NC | ||
Auxiliary Contact Configuration 1 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Soldering | ||
Minimum Operating Temperature -25°C | ||
Operational Current Ie 12A | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 110, 127V ac | ||
Maximum Operating Temperature 55°C | ||
Width 47.5mm | ||
Length 47.7mm | ||
Depth 47.7mm | ||
Standards/Approvals UL 60947-4-1, IEC/EN 60947-5-1, IEC/EN 60947-4-1, IEC/EN 60947-1, UL 60947-1 | ||
Pole and Throw Configuration 3P | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 3 Poles, 20A Current Rating - GJL1211009R8014
This contactor is an essential electrical control unit designed for reliable operational efficiency in various applications. With a Compact design measuring 47.7mm x 47.5mm x 47.7mm, it operates at a Coil voltage of 110-127V AC. This 3-pole device is perfectly suited for controlling power circuits up to 690V and a current rating of 20A, making it highly functional in demanding environments.
Features & Benefits
• Operates effectively at Coil voltages between 110 to 127V for versatility
• Handles a maximum contact voltage of 690V for robust performance
• Rated for 20A, facilitating high power applications with ease
• Features a configuration of 3NO and 1NC to manage diverse electrical needs
• Auxiliary contact configuration includes 1NC for added functionality
• Designed for DIN rail installation for convenient mounting
• Handles a maximum contact voltage of 690V for robust performance
• Rated for 20A, facilitating high power applications with ease
• Features a configuration of 3NO and 1NC to manage diverse electrical needs
• Auxiliary contact configuration includes 1NC for added functionality
• Designed for DIN rail installation for convenient mounting
Applications
• Utilised in industrial automation for controlling motor operations
• Ideal for switching in mechanical processes
• Great for controlling lighting and power distribution circuits
• Employed in control panels for enhanced operational efficiency
• Ideal for switching in mechanical processes
• Great for controlling lighting and power distribution circuits
• Employed in control panels for enhanced operational efficiency
What temperature range can this device operate within?
The operational temperature range is from -25°C to +55°C, ensuring reliability in both low and high heat environments.
How does the auxiliary contact configuration enhance functionality?
The 1NC auxiliary contact provides additional control capabilities, allowing for functions such as signalling and interlocking in complex systems.
What safety features are included to protect against overload?
This contactor is designed to manage specified current and voltage ratings safely, minimising risks associated with electrical overloads in the circuit it controls.
Can it be used in both indoor and outdoor environments?
While ideally suited for indoor use, it can operate outdoors as long as it is protected from direct exposure to environmental conditions that exceed its operational limits.
관련된 링크들
- RS PRO Steel Perforated DIN Rail, Top Hat Compatible, 500mm x 35mm x 7.5mm
- 6EP3334-8SB00-0AY0 | Siemens SITOP PSU8200 Switched Mode DIN Rail Power Supply, 120 → 230V ac ac Input, 24V dc dc Output, 10A Output,
- H3CR-A8 AC24-48/DC12-48 | Omron H3CR Series DIN Rail, Panel Mount Timer Relay, 12 → 48 V dc, 24 → 48V ac, 2-Contact, 0.05 s
- 52104571 | Lapp Cable Gland Adaptor, M20 Exterior Thread, M16 Interior Thread, Nickel Plated Brass, SKINDICHT Series
- 515015-601 | Latching Push Button Switch, IP67, Panel Mount
- Fluke LVD2 Non Contact Voltage Detector
- BD-02PMMS-LC7001 | Amphenol Industrial Circular Connector, 2 Contacts, Panel Mount, Plug, Male, IP67, Ceres Series
- RS PRO Type K Thermocouple 2m Length, 0.3mm Diameter → +600°C