ABB AF63 Contactor, 20V dc, 60 V dc Coil, 3-Pole, 30 kW 20V dc, 60 V dc, 3 NO, 690V

Subtotal (1 unit)*

₩2,082,580.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 10월 12일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩2,082,580.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
253-2018
제조사 부품 번호:
1SBL377001R7200
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Product Type

Contactor

Coil Voltage

20, 60V dc

Number of Poles

3

Contact Voltage

690V

Series

AF63

Power Rating

30kW

Function

Motor Control

Normal State Configuration

3 NO

Number of Auxiliary Contacts

0

Terminal Type

Screw

Contactor Application

Control Unit

Operational Current Ie

65A

Control Circuit Voltage Uc

20, 60V dc

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

70°C

Standards/Approvals

IEC 60077-1, EN 50155, CSA C22-2 N°14, IEC 60077-2, UL 508, TR CU 001/2011, IEC/EN 60947-4-1, IEC/EN 60947-1, IEC 61373

Depth

110mm

Width

70mm

Length

108mm

Pole and Throw Configuration

3P

COO (Country of Origin):
BG

ABB AF63 Series Contactor, 65A Operational Current, 690V Contact Voltage - 1SBL377001R7200


This contactor is a three-pole power switching device designed to control 3‑phase motors and general power circuits up to 690V. It accepts a wide DC control range and is suited to industrial control panels where Compact size and robust switching for motor starters and capacitor or bypass circuits are required.

Features & Benefits


• 65A rated operational current provides heavy-duty switching capacity
• 20 to 60V DC Coil enables flexible DC control circuit operation
• 3NO screw terminals simplify straightforward wiring connections
• 30kW AC-3 power rating supports medium-power motor loads
• -40 to +70°C ambient tolerance allows high-temperature installations
• 8kV impulse withstand voltage enhances insulation reliability

Applications


• Suitable for motor starter installations in automation panels
• Ideal for capacitor bank switching and power factor correction
• Used for bypass and changeover operations in industrial plants
• Can be used for DC power circuit switching in traction or control systems

What Terminal type does it use for main connections?


Main poles use screw terminals compatible with flexible and solid conductors and accept M6 screws with a 13x10mm connector.

What switching duty and frequency can be expected?


It is rated for up to 300 cycles per hour for AC-3 duties and a mechanical switching capability of 10 million operations.

How does it tolerate short voltage interruptions in the control supply?


The electronic Coil Interface is designed to withstand voltage dips and interruptions up to 20 MS while maintaining operation.

What protective device ratings correspond to short-circuit protection?


Recommended gG type fuse rating is 125A and maximum breaking capacities depend on system cosφ, with values provided for 440V and 690V systems.

관련된 링크들