ABB UA63 Contactor, 380V, 400 V Coil, 3-Pole, 115 A 400V, 415 V, 3 NO, 690V

Subtotal (1 unit)*

₩1,196,360.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 10월 12일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩1,196,360.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
253-2014
제조사 부품 번호:
1SBL371022R8500
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Product Type

Contactor

Coil Voltage

380, 400V

Number of Poles

3

Contact Voltage

690V

Contact Current

115A

Series

UA63

Mount Type

DIN Rail

Function

Capacitor Switching

Normal State Configuration

3 NO

Number of Auxiliary Contacts

0

Terminal Type

Screw

Control Circuit Voltage Uc

400, 415V

Contactor Application

Control Unit

Operational Current Ie

115A

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

70°C

Standards/Approvals

EU Directive 2011/65/EU, IEC 60947-4-1, VDE 0110, UL/CSA

Length

108mm

Width

70mm

Depth

110mm

Pole and Throw Configuration

3P

COO (Country of Origin):
BG

ABB UA63 Series Contactor, 115A Contact Current, 400 to 415V Control Circuit Voltage Uc - 1SBL371022R8500


This contactor is a three-pole control unit designed for switching capacitor banks in industrial electrical systems. It operates from standard industrial control voltages and is intended for installations where frequent capacitor switching and high Peak currents occur. The device is built for DIN-rail mounting and is supplied with screw-type connections for main conductors.

Features & Benefits


• 115A rated operational current provides high continuous load handling
• Accepts inrush peaks up to 100 times nominal current for capacitor switching
• Coil designed for 400 to 415V control voltage ensuring compatibility with AC control systems
• Electrical durability up to 100,000 operating cycles for extended service life
• Operates reliably from -40°C to +70°C for wide ambient conditions
• Maximum breaking capacity 1,300A at 440V supports heavy fault interruption

Applications


• Suitable for power factor correction in industrial motor installations
• Ideal for switching capacitor banks in distribution panels
• Can be used for centralised reactive power management in factories
• Suitable for replacing worn contactors in automated capacitor banks

What is the expected mechanical endurance under regular operation?


Mechanical life is specified at 10 million cycles with a maximum mechanical switching frequency of 3,600 cycles per hour.

How should capacitors be managed to ensure correct switching behaviour?


Capacitors must be discharged so residual voltage at terminals is ≤50V before re-energisation to meet rated electrical durability.

Which voltages and power ratings are supported for AC-3 switching?


AC-3 power capability includes up to 45kvar at 400/415V 40°C and up to 70kvar at 690V 40°C with reduced values at higher ambient temperatures.

What are the Terminal connection options and conductor sizes?


Main circuit screw terminals accept flexible conductors with ferrules and rigid conductors

main circuit capacity supports flexible 6 to 16mm² and rigid 6 to 25mm².

What insulation and impulse withstand performance does it offer?


Rated insulation voltage is 1,000V for IEC use and rated impulse withstand voltage is 8kV.

관련된 링크들