ABB AF50 Contactor, 3-Pole, 22 kW 130V, 48 V, 3 NO, 690V

Subtotal (1 unit)*

₩1,422,681.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 7월 20일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩1,422,681.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
253-1997
제조사 부품 번호:
1SBL357001R6900
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Coil Voltage

130, 40V

Product Type

Contactor

Number of Poles

3

Contact Voltage

690V

Power Rating

22kW

Series

AF50

Function

Motor Control

Normal State Configuration

3 NO

Number of Auxiliary Contacts

0

Terminal Type

Screw

Operational Current Ie

100A

Contactor Application

Control Unit

Control Circuit Voltage Uc

130, 48V

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

55°C

Standards/Approvals

CSA C22-2 N°14, EN 50155, IEC 60077-1, IEC 60077-2, IEC 61373, IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, TR CU 001/2011

Depth

110mm

Width

70mm

Length

108mm

Pole and Throw Configuration

3P

COO (Country of Origin):
BG

ABB AF50 Series Contactor, 100A Operational Current, 22kW Power Rating - 1SBL357001R6900


This contactor is a three-pole switching device designed to control 3-phase motors and general power circuits up to 690 V. It accepts a wide control-voltage window on AC 50/60 Hz or DC supplies, allowing the same unit to be used across varying supply conditions and in installations subject to voltage dips or brief interruptions.

Features & Benefits


• 100A rated current delivers high-load switching capacity
• 22 kW AC-3 power rating supports medium-power motors
• 48 to 130V control range permits wide Coil supply compatibility
• 3NO main contact arrangement enables straightforward motor starters
• Screw terminals allow secure connections for conductors
• Can tolerate short control-voltage interruptions, improving uptime

Applications


• Suitable for switching 3-phase motor starters in industrial panels
• Ideal for bypass and capacitor switching in power circuits
• Used for lighting and DC power circuit control in traction systems
• Can be used for retrofit replacement of like-for-like contactors

What ambient temperatures can it operate within when fitted with an overload relay?


When mounted close to a thermal overload relay it is specified for operation between -25 °C and +55 °C.

What insulation and impulse withstand levels does it meet for industrial environments?


It is rated for 1000V insulation (per IEC/EN) with an 8 kV impulse withstand voltage.

How does the Coil consumption affect control wiring design?


Holding consumption is low at 2.8 V·A while pull-in requirement is 210 V·A at maximum rated control voltage, which should be considered when sising control transformers and protection.

What mechanical and electrical switching duties are supported?


Electrical switching frequency allows up to 300 cycles/hour for AC-1 and AC-3 duties with a mechanical switching endurance of 300 cycles/hour.