ABB UA30 Contactor, 380V, 400 V Coil, 3-Pole, 16 A 380V, 400 V, 3 NO, 690V

Subtotal (1 unit)*

₩612,980.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 2 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩612,980.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
253-1977
제조사 부품 번호:
1SBL281022R8510
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Coil Voltage

380, 400V

Product Type

Contactor

Number of Poles

3

Contact Voltage

690V

Contact Current

16A

Series

UA30

Function

Capacitor Switching

Mount Type

DIN Rail

Normal State Configuration

3 NO

Auxiliary Contact Configuration

1 NO

Number of Auxiliary Contacts

1

Terminal Type

Screw

Minimum Operating Temperature

-40°C

Contactor Application

Control Unit

Operational Current Ie

16A

Control Circuit Voltage Uc

380, 400V

Maximum Operating Temperature

55°C

Depth

90mm

Width

54mm

Length

109mm

Standards/Approvals

CCC, CSA, RoHS, UL

Pole and Throw Configuration

3P

COO (Country of Origin):
BG

ABB UA30 Series Contactor, 16A Operational Current, 380 to 400V Control Circuit Voltage Uc - 1SBL281022R8510


This contactor is a compact, three-pole control unit designed for capacitor switching in industrial electrical installations. It operates with an AC control circuit at 380 to 400V (50Hz) or 400 to 415V (60Hz) and is intended for DIN-rail mounting in panels where controlled switching of capacitor banks is required.

Features & Benefits


• 16A operational current for handling moderate load currents
• Accepts Peak inrush up to 100x nominal rms current for capacitors
• Withstands up to 45kvar at 690V for high-voltage capacitor banks
• Mechanical life rated to 10 million operations for long service
• Screw Terminal connections enabling secure field wiring
• IP20 Coil Terminal protection for Basic access safety

Applications


• Suitable for switching capacitor banks in power-factor correction schemes
• Ideal for panel-mounted reactive power control modules
• Used for modular industrial control cubicles on DIN rail
• Can be used as a replacement for Compact Block contactors in distribution panels

What are the expected switching speeds for control response?


Coil energisation closes main contacts within 8 to 21 MS and releases NO contacts within 4 to 11 MS, enabling timely switching of capacitor circuits.

What temperature range can it reliably operate in near the device?


It is suitable for operation in free Air from −40°C up to +55°C when supplied at 0.85 to 1.1Uc, with higher-temperature ratings available at nominal Uc.

What are the connection capacities for main and auxiliary conductors?


Main circuit cables accept flexible conductors with ferrules from 2.5 to 10mm² and rigid conductors 2.5 to 16mm² while auxiliary terminals take 0.75 to 4mm² depending on conductor type.

How does it behave under fault conditions regarding breaking capacity?


Maximum breaking capacity reaches 820A at 440V (cosφ = 0.45) and 340A at 690V (cosφ = 0.45), suitable for typical industrial short-circuit scenarios.