ABB UA16 Contactor, 110V Coil, 3-Pole, 3 NO, 690V

Subtotal (1 unit)*

₩290,072.25

Add to Basket
수량 선택 또는 입력
재고있음
  • 4 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩290,072.25

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
253-1937
제조사 부품 번호:
1SBL181022R8410
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Product Type

Contactor

Coil Voltage

110V

Number of Poles

3

Contact Voltage

690V

Series

UA16

Mount Type

DIN Rail

Function

Capacitor Switching

Normal State Configuration

3 NO

Auxiliary Contact Configuration

1 NO

Number of Auxiliary Contacts

1

Terminal Type

Screw

Control Circuit Voltage Uc

110V

Contactor Application

Control Unit

Operational Current Ie

6A

Minimum Operating Temperature

-60°C

Maximum Operating Temperature

80°C

Width

44mm

Standards/Approvals

RoHS Status, EU Directive 2011/65/EU

Depth

74mm

Length

74mm

Pole and Throw Configuration

3P

COO (Country of Origin):
BG

ABB UA16 Series Contactor, 110V Coil Voltage, 6A Operational Current - 1SBL181022R8410


This contactor is a three-pole control unit designed for switching capacitor banks in industrial electrical systems. It operates from AC control circuits at 50/60 Hz and is suited to applications where precise capacitor switching and Compact DIN-rail mounting are required.

Features & Benefits


• 6A operational current supports moderate load switching
• 110 to 120V control circuit enables 50/60 Hz compatibility
• 690V main contact rating handles high-voltage capacitor banks
• 1 NO auxiliary screw Terminal provides simple signalling integration
• -60 °C to 80 °C temperature range allows extreme storage and use
• 3,600 mechanical cycles per hour supports frequent operation

Applications


• Suitable for capacitor bank switching in power factor correction panels
• Ideal for industrial automation control cabinets on DIN rail
• Used for switching capacitors with high Peak inrush currents within limits
• Can be used where Compact width and shallow depth are required

What inrush current conditions can it tolerate when switching capacitors?


It accepts capacitor switching where inrush peaks are up to 100 times the nominal RMS current and requires capacitors to be discharged to ≤50V before re-energisation.

How does the unit connect within a control panel?


Main and auxiliary circuits use screw terminals with cable clamps

main poles are delivered in the open position for straightforward wiring.

What are the Coil consumption and operate times?


Average pull-in and holding values vary with frequency

pull-in values are approximately 70 to 74 V·A and 70 to 80 V·A depending on 50/60 Hz, with operate times between 10 to 26 MS for closing and 4 to 11 MS for opening sequences.

Which protective devices are appropriate for short-circuit protection?


Short-circuit protective devices include gG fuses in recommended ranges and specific breaking capacities at 440V and 690V according to cos φ conditions.