Omron, J7TKN Thermal Overload Relay 1 NO/1 NC, Trip Dial: 8 → 11 A, 10A F.L.C, 44.419kA Contact Rating, 44.301 kW, 690V
- RS 제품 번호:
- 214-7772
- 제조사 부품 번호:
- J7TKN-A-11
- 제조업체:
- Omron
Subtotal (1 unit)*
₩426,080.00
일시적 품절
- 2027년 3월 01일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩426,080.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 214-7772
- 제조사 부품 번호:
- J7TKN-A-11
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Thermal Overload Relay | |
| FLC Motor Rating | 10A | |
| Relay Contact Current | 44.419kA | |
| Series | J7TKN | |
| Mount Type | Direct | |
| Pole and Throw Configuration | 3P | |
| Power Rating | 44.301kW | |
| Normal State Configuration | 1 NO/1 NC | |
| Reset Method | Manual | |
| Width | 45mm | |
| Number of Auxiliary Contacts | 2 | |
| Adjustable Current Range | 8 → 11 A | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 60°C | |
| Contact Voltage | 690V | |
| Length | 95mm | |
| Depth | 70mm | |
| Standards/Approvals | VDE 0660, UL, EN/IEC 60947-4-1, IEC 60947-4-1 | |
| Control Voltage | 690V ac | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Thermal Overload Relay | ||
FLC Motor Rating 10A | ||
Relay Contact Current 44.419kA | ||
Series J7TKN | ||
Mount Type Direct | ||
Pole and Throw Configuration 3P | ||
Power Rating 44.301kW | ||
Normal State Configuration 1 NO/1 NC | ||
Reset Method Manual | ||
Width 45mm | ||
Number of Auxiliary Contacts 2 | ||
Adjustable Current Range 8 → 11 A | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 60°C | ||
Contact Voltage 690V | ||
Length 95mm | ||
Depth 70mm | ||
Standards/Approvals VDE 0660, UL, EN/IEC 60947-4-1, IEC 60947-4-1 | ||
Control Voltage 690V ac | ||
Omron J7TKN Series Thermal Overload Relay, 8 to 11A Adjustable Current Range, 690V Contact Voltage - J7TKN-A-11
This thermal overload relay provides thermal motor protection for three-phase systems, designed to interrupt motor circuits when sustained overcurrent occurs. It is intended for direct mounting in control panels and contactor assemblies, offering adjustable trip settings for correct coordination with motor ratings and protection schemes.
Features and Benefits:
• Adjustable current range 8to11A for precise protection setting
• Manual reset mechanism for controlled restart after trip
• Rated for 690V operation enabling high-voltage applications
• Three-pole configuration delivering phase-by-phase disconnect capability
• Two auxiliary contacts 1NO1NC for signalling and interlock functions
• Suitable for motors up to 44.301kW based on relay rating
• Manual reset mechanism for controlled restart after trip
• Rated for 690V operation enabling high-voltage applications
• Three-pole configuration delivering phase-by-phase disconnect capability
• Two auxiliary contacts 1NO1NC for signalling and interlock functions
• Suitable for motors up to 44.301kW based on relay rating
Applications
• Suitable for protection of 10A FLC motors in industrial drives
• Used with contactors in automated motor control panels
• Ideal for retrofit protection in manufacturing plant motor circuits
• Can be used for motor overload supervision in HVAC systems
• Used for safeguarding pumps and compressors in process lines
• Used with contactors in automated motor control panels
• Ideal for retrofit protection in manufacturing plant motor circuits
• Can be used for motor overload supervision in HVAC systems
• Used for safeguarding pumps and compressors in process lines
What environmental temperatures can it tolerate during operation?
It operates within a temperature band from -25°C to 60°C, accommodating typical industrial ambient conditions.
How does the relay Interface electrically with control systems?
Control and contact voltage ratings are 690V AC, and the relay provides two auxiliary contacts with one normally open and one normally closed contact for status feedback.
What standards guide its electrical and safety performance?
It is manufactured to meet VDE 0660, UL and EN/IEC 60947-4-1 requirements applicable to motor control devices.
How is the relay physically mounted and what are its form-factor considerations?
It is designed for direct mounting and presents a Compact footprint with width 95mm length 45mm depth 70mm for straightforward panel installation.
관련된 링크들
- H3CR-A8 AC24-48/DC12-48 | Omron H3CR Series DIN Rail, Panel Mount Timer Relay, 12 → 48 V dc, 24 → 48V ac, 2-Contact, 0.05 s
- RS PRO Type K Thermocouple 2m Length, 0.3mm Diameter → +600°C
- BD-02PMMS-LC7001 | Amphenol Industrial Circular Connector, 2 Contacts, Panel Mount, Plug, Male, IP67, Ceres Series
- Fluke LVD2 Non Contact Voltage Detector
- 52104571 | Lapp Cable Gland Adaptor, M20 Exterior Thread, M16 Interior Thread, Nickel Plated Brass, SKINDICHT Series
- RS PRO Steel Perforated DIN Rail, Top Hat Compatible, 500mm x 35mm x 7.5mm
- 515015-601 | Latching Push Button Switch, IP67, Panel Mount