Energizer A76 Button Battery, 1.5 V, 11.6 mm Diameter, 2 Pack

Subtotal (1 pack of 2 units)*

₩2,580.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 10월 19일 부터 711 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
팩
한팩당
한팩당*
1 +₩2,580.00₩1,290.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
683-377
제조사 부품 번호:
7638900083071
제조업체:
Energizer
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Energizer

Battery Size

A76

Product Type

Button Battery

Chemistry

Manganese Dioxide

Nominal Voltage

1.5V

Battery Capacity

175mAh

Diameter

11.6mm

Number of Batteries

2

Termination Type

Flat Contact

NEDA Code

1166 A

Standards/Approvals

No

Weight

1.85g

IEC Code

Iec-Lr44

제외

COO (Country of Origin):
CN

Energizer Button Battery, 1.5V Nominal Voltage, 175mAh Capacity - 7638900083071


This button battery is a small 1.5V coin cell designed to supply portable electronic devices that require compact, steady power. It uses a manganese dioxide chemical system and is intended for applications that demand continuous low-drain operation with occasional high-rate pulses. The pack contains two cells and is suited to items where long service life at light loads is important.

Features and Benefits:


• 175mAh capacity provides extended runtime under light loads
• 1.5V nominal output maintains stable voltage for electronics
• Flat contact termination enables simple device installation
• Low impedance (5-15Ω at 40Hz) supports Pulse currents
• Typical weight 1.85g minimises added device mass

Applications


• Suitable for watches and small timing devices
• Suitable for handheld calculators and remote controls
• Used with small toys requiring Compact power sources
• Used for medical instruments with low continuous drain
• Can be used for LED indicators and small sensors

How long will the cell operate under continuous light load?


At a continuous drain of 0.191mA (6.8KΩ load) it provides about 915 hours to 0.9V.

What happens to the cell as it discharges?


The cell may bulge during discharge but will not exceed its specified maximum height.

How is capacity measured for these cells?


Capacity is determined at 21°C using a 6.8KΩ continuous drain until cut‑off at 0.9V.

What is the typical internal impedance and its significance?


Measured at 40Hz, impedance ranges 5-15Ω which allows brief high-rate pulses while supplying low-drain devices.

What form factor and chemistry should be expected?


The cells use a manganese dioxide system in a miniature coin format with flat contacts for installation.