ABB Auxiliary Contact, 2 Contact, 1 NO/1 NC, CAF6, Surface, 6 A, 690V, GJL1201330R0001

N

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

Subtotal (1 unit)*

₩13,318.50

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 6월 18일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩13,318.50

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
721-671
제조사 부품 번호:
GJL1201330R0001
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Number of Contacts

2

Product Type

Auxiliary Contact

Normal State Configuration

1 NO/1 NC

Series

CAF6

Contact Current

6A

Mount Type

Surface

Terminal Type

Screw

Pole and Throw Configuration

2P

Contact Voltage

690V

Minimum Operating Temperature

-25°C

Operational Current Ie

4A

Rated Insulation Voltage Ui

690V

Maximum Operating Temperature

55°C

Standards/Approvals

IEC/EN 60947-4-1, UL 60947-4-1, UL 60947-1, IEC/EN 60947-1, IEC/EN 60947-5-1

COO (Country of Origin):
DE

ABB CAF6 Series Auxiliary Contact, 6A Contact Current, 690V Contact Voltage - GJL1201330R0001


This auxiliary contact is a front‑mounting accessory designed to add monitoring and signalling capability to mini contactors in industrial control systems. It provides a compact, surface‑mount solution with screw terminals for secure wiring and is intended for use where additional auxiliary switching is required alongside primary contactor functions.

Features & Benefits


• 2P configuration delivering one NO and one NC contact for state feedback
• Operational current of 4 A enabling control circuit switching
• Contact rating 6 A at up to 690V for diverse auxiliary loads
• Rated insulation voltage 690V supporting high‑voltage isolation
• Screw Terminal connections for reliable field termination
• Ambient operating range from -25 °C to 55 °C for harsh environments

**Applications**


• Suitable for retrofitting mini contactors requiring auxiliary switching
• Used with control panels to signal contactor position to PLCs
• Ideal for integration in motor starter assemblies for interlock logic
• Can be used for alarm circuits monitoring contactor states

What wiring sizes can be accommodated in the terminals?


Terminals accept flexible conductors with ferrules and rigid conductors

flexible 2x1 to 2.5 mm² and rigid up to 2x1 to 4 mm² are supported.

How is mechanical mounting handled for installation?


It is intended for surface/front mounting onto compatible contactor frames to align auxiliary contacts with main device actuation.

What environmental limits should installers observe?


The unit can be stored between -40 °C and +80 °C and operated up to an altitude of 2000 m.

Which standards does it meet for industrial use?


It complies with IEC/EN 60947 series requirements and corresponding UL standards for control equipment.

What torque should be applied to Terminal screws?


Tightening torque for the auxiliary circuit terminals is 0.8 to 1.1 N·m

UL/CSA torque Value is 7 in·lb.