Endress+Hauser 2 Channel Zener Barrier, ATEX
- RS 제품 번호:
- 316-256
- 제조사 부품 번호:
- RN22-8L2BPA
- 제조업체:
- Endress+Hauser
Subtotal (1 unit)*
₩500,160.00
일시적 품절
- 2026년 10월 19일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩500,160.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 316-256
- 제조사 부품 번호:
- RN22-8L2BPA
- 제조업체:
- Endress+Hauser
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Endress+Hauser | |
| Product Type | Zener Barrier | |
| Number of Channels | 2 | |
| Barrier Type | Zener Barrier | |
| Mount Type | DIN Rail | |
| Hazardous Area Certification | ATEX | |
| Safety Current Resistance | 500Ω | |
| Terminal Type | Plug-In | |
| Supply Voltage | 24V dc | |
| IP Rating | IP20 | |
| Maximum Safety Current | 400mA | |
| Maximum Safety Voltage | 24V | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | RoHS | |
| 모두 선택 | ||
|---|---|---|
브랜드 Endress+Hauser | ||
Product Type Zener Barrier | ||
Number of Channels 2 | ||
Barrier Type Zener Barrier | ||
Mount Type DIN Rail | ||
Hazardous Area Certification ATEX | ||
Safety Current Resistance 500Ω | ||
Terminal Type Plug-In | ||
Supply Voltage 24V dc | ||
IP Rating IP20 | ||
Maximum Safety Current 400mA | ||
Maximum Safety Voltage 24V | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals RoHS | ||
- COO (Country of Origin):
- DE
Endress+Hauser 2 Channel Zener Barrier
Intrinsically safe active barrier that provides power and safety to analog instrument loops and SIL systems, establishing a reliable signal link between field devices and process control level.
The RN22 is a 1- or 2-channel active barrier, power supply or signal doubler for safe separation of 4 to 20 mA standard signal circuits. The device safely powers analog instrument loops and safety instrumented systems up to SIL 2, SC 3 (according to IEC 61508). The HART® transparent interface device establishes a reliable signal link between field devices and process control. It interfaces with 2- or 4-wire instruments in Zone 2 hazardous areas and provides a second, galvanically isolated signal output acc. to NAMUR NE 175. This opens a second channel for the process optimization domain without affecting the traditional automation system.
Connection lugs integrated on front for HART communicators
Simple and quick wiring with plug in terminals
Features & Benefits
Active barrier for safe separation of standard signal circuits
Compact housing
Quick and easy wiring
Intrinsic safety for operation in hazardous areas (Zone 2)
For safety-oriented applications up to SIL 2 (SC 3) in accordance with IEC61508 (optional)
관련된 링크들
- Endress+Hauser Zener Barrier, Current, ATEX
- Endress+Hauser 2 Channel Galvanic Barrier, Zone 2