Alpha Wire Pro-Tekt Series Data Cable, 5 Pairs, 0.35 mm², 50 m, Grey Sheath Polyvinyl Chloride

Subtotal (1 reel of 50 metres)*

₩320,440.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 2 개 단위 배송 준비 완료
  • 추가로 2026년 10월 20일 부터 2 개 단위 배송
  • 추가로 2026년 10월 27일 부터 2 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당
릴당
미터당*
1 +₩320,440.00₩6,408.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
740-4840
제조사 부품 번호:
B964052 GE321
제조업체:
Alpha Wire
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Alpha Wire

Product Type

Data Cable

Number of Pairs

5

Cross Sectional Area

0.35mm²

Number of Cores

10

Cable Length

50m

Jacket Colour

Grey

Outside Diameter

7.47mm

Conductor Type

Copper

Minimum Operating Temperature

-30°C

Jacket Material

Polyvinyl Chloride

Maximum Operating Temperature

105°C

Standards/Approvals

CE, CSA Certified, UL

Fire Behaviour

Flame Retardant

Size of Strands

30AWG

Conductor Material

Tin Copper Wire

Series

Pro-Tekt

Voltage

300V

Core Strands

7 x 30AWG

Number of Strands

7

Belden Pro-Tekt Series Data Cable, 50m Cable Length, 300V Voltage - B964052 GE321


This data cable is a multi-pair communication conductor designed for industrial signal and control wiring in automation, electronics and electrical systems. It combines a grey PVC outer sheath with a cabled assembly of five twisted pairs and an overall foil shield to provide organised pair routing and Basic EMI protection for medium-voltage signal distribution.

Features & Benefits


• 0.35mm2 conductors provide consistent signal-carrying capacity
• 7-strand tinned copper conductors reduce breakage risk
• Flame-retardant construction limits fire propagation
• Rated for -30°C to 105°C operation for varied environments
• 300V voltage rating supports common control systems
• Foil shield and drain support improved noise rejection

**Applications**


• Suitable for factory automation signal and control circuits
• Ideal for industrial panels and instrumentation wiring
• Used with PLCs and distributed I/O networks
• Can be used for machine tool harnessing and cable runs
• Suitable for installations requiring PVC-jacketed multi-pair cable

What conductor make-up ensures flexibility for routing through trays?


Each conductor comprises seven tinned copper strands that give flexibility and mechanical resilience during bending and installation.

How is pair identification handled for termination?


Pairs are colour-coded with white paired to black, brown, red, Orange and yellow to simplify pair selection at termination points.

What shielding arrangement assists with electromagnetic compatibility?


An aluminium/mylar wrap with an internal drain conductor is applied with the foil facing inward to provide a continuous return path and reduce interference.

How is the assembly constructed to maintain pair integrity?


Pairs are cabled together with specified twists per foot and a clear mylar core wrap to preserve geometry and minimise crosstalk.

What physical handling limits should be observed during installation?


The cable has a maximum pull tension of 60 lb and a recommended bend radius of 10x the cable diameter for safe routing.