Alpha Wire Pro-Tekt Series Data Cable, 1 Pairs, 0.35 mm², 50 m, Grey Sheath Polyvinyl Chloride

Subtotal (1 reel of 50 metres)*

₩171,970.50

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 7월 07일 부터 8 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당
릴당
미터당*
1 +₩171,970.50₩3,439.80

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
740-4831
제조사 부품 번호:
B964012 GE321
제조업체:
Alpha Wire
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Alpha Wire

Product Type

Data Cable

Number of Pairs

1

Cross Sectional Area

0.35mm²

Cable Length

50m

Jacket Colour

Grey

Outside Diameter

4.34mm

Conductor Type

Copper

Jacket Material

Polyvinyl Chloride

Minimum Operating Temperature

-30°C

Maximum Operating Temperature

105°C

Standards/Approvals

CE, CSA Certified, UL

Voltage

300V

Conductor Material

Tin Copper Wire

Series

Pro-Tekt

Fire Behaviour

Flame Retardant

Core Strands

7

Belden Pro-Tekt Series Data Cable, 50m Cable Length, Grey Jacket - B964012 GE321


This data cable is a single-pair tin-plated copper cable intended for industrial communication and control wiring. Designed for use in automation, electrical and electronic installations, it delivers signal transmission in environments requiring flame-retardant construction and a flexible conductor.

Features & Benefits


• 0.35 mm2 conductor for consistent current-carrying capacity
• Tin-plated copper 7-strand conductor for improved termination
• Flame-retardant PVC jacket for reduced fire propagation risk
• Rated for 300V to suit common low-voltage systems
• Operating range -30 to 105°C for high-temperature environments

**Applications**


• Suitable for control-panel interconnects in manufacturing plants
• Ideal for sensor and actuator wiring in automated systems
• Used with fieldbus and serial communication runs inside cabinets
• Can be used for machine-tool internal signal circuits

How is the conductor arranged internally?


The core comprises a single twisted pair with a 7-strand tin-plated copper conductor and an internal mylar core wrap to maintain pair geometry.

What shielding is provided to reduce interference?


An aluminium/mylar foil shield with an accompanying drain conductor is included to provide coverage and allow easy termination to earth.

How is the outer sheath constructed for installation durability?


The outer sheath is a nominal 0.032 wall PVC with a ripcord for simplified jacket removal during termination.

What electrical characteristics should engineers expect for impedance and capacitance?


Characteristic impedance is nominally 48 Ω, mutual capacitance about 39 pF/ft and ground capacitance about 70 pF/ft at 1 kHz.

관련된 링크들