Belden 3107ELW Series Twisted & Multipair Industrial Cable, 2 Pairs, 305 m Low Smoke Zero Halogen
- RS 제품 번호:
- 631-734
- 제조사 부품 번호:
- 3107ELW.00305
- 제조업체:
- Belden
Subtotal (1 reel of 305 metres)*
₩6,365,591.64
재고있음
- 1 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩6,365,591.64 | ₩20,871.76 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 631-734
- 제조사 부품 번호:
- 3107ELW.00305
- 제조업체:
- Belden
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Belden | |
| Product Type | Twisted & Multipair Industrial Cable | |
| Number of Pairs | 2 | |
| Cable Length | 305m | |
| Minimum Operating Temperature | -45°C | |
| Jacket Material | Low Smoke Zero Halogen | |
| Maximum Operating Temperature | 80°C | |
| Standards/Approvals | EU Directive 2015/863/EU (RoHS 2 amendment), UKCA, DMX-512, EU CE, EU Directive 2011/65/EU (RoHS 2) | |
| Series | 3107ELW | |
| 모두 선택 | ||
|---|---|---|
브랜드 Belden | ||
Product Type Twisted & Multipair Industrial Cable | ||
Number of Pairs 2 | ||
Cable Length 305m | ||
Minimum Operating Temperature -45°C | ||
Jacket Material Low Smoke Zero Halogen | ||
Maximum Operating Temperature 80°C | ||
Standards/Approvals EU Directive 2015/863/EU (RoHS 2 amendment), UKCA, DMX-512, EU CE, EU Directive 2011/65/EU (RoHS 2) | ||
Series 3107ELW | ||
- COO (Country of Origin):
- NL
Belden 3107ELW Series Twisted & Multipair Industrial Cable, 305m Cable Length, 8.9mm Outside Diameter - 3107ELW.00305
This twisted & multipair industrial cable is designed for signal and control duties in demanding industrial environments. It combines a flexible stranded conductor with a halogen-minimising outer sheath to provide a practical transmission medium for paired circuits where restricted smoke and low-toxicity emissions are required. The construction suits use where moderate voltage capacity and a wide operating temperature range are necessary.
Features & Benefits
• 7x30 stranded tinned copper conductor provides flexibility and continuity
• Low Smoke Zero Halogen jacket reduces toxic emissions during combustion
• Rated to 300V to support common control and signalling circuits
• Complies with IEC60332-1-2 for Basic flame propagation resistance
• Operational from -45°C to 80°C for varied indoor/outdoor conditions
• 2 paired cores permit straightforward balanced signalling and audio
• Low Smoke Zero Halogen jacket reduces toxic emissions during combustion
• Rated to 300V to support common control and signalling circuits
• Complies with IEC60332-1-2 for Basic flame propagation resistance
• Operational from -45°C to 80°C for varied indoor/outdoor conditions
• 2 paired cores permit straightforward balanced signalling and audio
Applications
• Suitable for DMX512 lighting control installations requiring LSZH cabling
• Ideal for industrial automation signal runs between control panels
• Used with audio systems where paired conductors are needed for line signals
• Can be used for temporary or permanent wiring on production lines
• Suitable for installations requiring RoHS conformity and UKCA marking
• Ideal for industrial automation signal runs between control panels
• Used with audio systems where paired conductors are needed for line signals
• Can be used for temporary or permanent wiring on production lines
• Suitable for installations requiring RoHS conformity and UKCA marking
What conductor finish helps prevent corrosion in humid environments?
The copper conductors are tinned which improves oxidation resistance for better long-term connectivity in damp conditions.
How is fire performance quantified for use in cable trays?
The cable meets IEC60332-1-2, indicating it resists vertical flame spread under the specified test, reducing risk of propagation in stacked runs.
What jacket attributes assist in confined-space installations?
The sheath is formulated to emit low smoke and low halogen content when exposed to fire, lowering toxic gas concentration in enclosed areas.
What mechanical flexibility can installers expect from the cores?
Each core uses multiple fine strands to provide enhanced bendability, facilitating routing through ducts and conduits without excessive stiffness.
How is environmental compliance addressed for restricted-hazard sites?
The cable conforms to RoHS directives and carries UKCA marking, aligning material content with regulated substance limits.
관련된 링크들
- Belden 3107ELW Series Twisted & Multipair Industrial Cable, 2 Pairs, 500 m Low Smoke Zero Halogen
- Belden 8471ELW Series Twisted & Multipair Industrial Cable, 1 Pairs, 305 m Low Smoke Zero Halogen
- Belden 8762ELW Series Twisted & Multipair Industrial Cable, 1 Pairs, 305 m Low Smoke Zero Halogen
- Belden 8777ELW Series Twisted & Multipair Industrial Cable, 3 Pairs, 305 m Low Smoke Zero Halogen
- Belden 8760ELW Series Twisted & Multipair Industrial Cable, 1 Pairs, 500 m Low Smoke Zero Halogen
- Belden 9536ELW Series Twisted & Multipair Industrial Cable, 3 Pairs, 500 m Low Smoke Zero Halogen
- Belden 9729ELW Series Twisted & Multipair Industrial Cable, 2 Pairs, 500 m Low Smoke Zero Halogen
- Belden 3107ELV Series Twisted & Multipair Industrial Cable, 2 Pairs, 500 m Low Smoke Zero Halogen