Belden 9504NH Series Twisted Pair Cable, 4 Pairs, 22 AWG, 1000 m Low Smoke Zero Halogen

Subtotal (1 reel of 1000 metres)*

₩5,057,248.95

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 7월 17일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당
릴당
미터당*
1 +₩5,057,248.95₩5,058.30

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
631-725
제조사 부품 번호:
9504NH.001000
제조업체:
Belden
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Belden

Product Type

Twisted Pair Cable

Number of Pairs

4

Cross Sectional Area

22 AWG

Cable Length

1000m

Minimum Operating Temperature

-15°C

Jacket Material

Low Smoke Zero Halogen

Maximum Operating Temperature

80°C

Standards/Approvals

RoHS

Series

9504NH

Voltage

300V

COO (Country of Origin):
NL

Belden 9504NH Series Twisted & Multipair Industrial Cable, 1000m Cable Length, 24AWG Cross Sectional Area - 9504NH.001000


This twisted & multipair industrial cable is designed for signal and control transmission in industrial environments, providing Durable performance across a wide temperature range. It combines multiple screened pairs in a single assembly with a low-emission sheath suited to installations where reduced toxic and corrosive gases are required during combustion.

Features and Benefits:


• Four pairs enhance conductor count for multi-channel signals
• 24AWG tinned copper conductors support corrosion resistance
• Stranded seven-core construction improves flexibility for routing
• Rated to 300V for typical control and communication circuits
• LSZH chrome-coloured sheath reduces hazardous emissions in fire
• Operates between -15°C and 80°C for varied ambient conditions

Applications


• Suitable for factory automation control wiring
• Ideal for industrial communication between controllers and I/O modules
• Used for sensor and actuator cabling in machine assemblies
• Can be used for panel-to-panel multi-channel signal runs

How is the cable supplied for large projects?


It is available on a 1000 m bulk reel to facilitate long continuous runs and reduce jointing.

What standards govern its fire performance?


The cable meets IEC 60332-1-2 and IEC 60332-3-24 requirements for flame propagation and grouping behaviour.

Which environmental restriction is addressed by the jacket material?


The low smoke zero halogen sheath minimises toxic and acidic gas release during combustion for safer evacuation and reduced equipment corrosion.

What is the cable outer diameter for conduit planning?


The cable measures 6.9mm overall, allowing accurate fill calculations for trays and conduits.