Alpha Wire XTRA-GUARD 2 Series Data Cable, 2 Pairs, 0.35 mm², 30 m, Black Sheath Polyvinyl Chloride
- RS 제품 번호:
- 409-230
- 제조사 부품 번호:
- 25482 BK005
- 제조업체:
- Alpha Wire
Subtotal (1 reel of 30 metres)*
₩658,086.00
재고있음
- 추가로 2026년 5월 11일 부터 21 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩658,086.00 | ₩21,935.55 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 409-230
- 제조사 부품 번호:
- 25482 BK005
- 제조업체:
- Alpha Wire
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Alpha Wire | |
| Product Type | Data Cable | |
| Number of Pairs | 2 | |
| Cross Sectional Area | 0.35mm² | |
| Cable Length | 30m | |
| Jacket Colour | Black | |
| Outside Diameter | 5.99mm | |
| Conductor Type | Copper | |
| Minimum Operating Temperature | -30°C | |
| Jacket Material | Polyvinyl Chloride | |
| Maximum Operating Temperature | 90°C | |
| Standards/Approvals | CSA, UL, CE | |
| Fire Behaviour | Flammability Test: VW-1 | |
| Conductor Material | Tin Copper Wire | |
| Series | XTRA-GUARD 2 | |
| Voltage | 300V | |
| Core Strands | 7 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Alpha Wire | ||
Product Type Data Cable | ||
Number of Pairs 2 | ||
Cross Sectional Area 0.35mm² | ||
Cable Length 30m | ||
Jacket Colour Black | ||
Outside Diameter 5.99mm | ||
Conductor Type Copper | ||
Minimum Operating Temperature -30°C | ||
Jacket Material Polyvinyl Chloride | ||
Maximum Operating Temperature 90°C | ||
Standards/Approvals CSA, UL, CE | ||
Fire Behaviour Flammability Test: VW-1 | ||
Conductor Material Tin Copper Wire | ||
Series XTRA-GUARD 2 | ||
Voltage 300V | ||
Core Strands 7 | ||
Belden XTRA-GUARD 2 Series Data Cable, 30m Cable Length, Black Jacket - 25482 BK005
This data cable is a 2-pair communication cable designed for industrial and automation environments, providing screened pair construction and a robust outer jacket for reliable signal transmission in installations requiring moderate mechanical protection and temperature resilience.
Features & Benefits
• 0.35mm² tinned copper conductor for consistent conductivity and Flexibility
• 7-strand conductor construction allowing improved Flex life
• Shielded foil with drain for reduced electromagnetic interference
• PVC outer jacket rated to 90°C for elevated operating temperatures
• VW-1 flame-retardant rating enhancing fire safety in installations
• 300V voltage rating suitable for standard control and signal circuits
• 7-strand conductor construction allowing improved Flex life
• Shielded foil with drain for reduced electromagnetic interference
• PVC outer jacket rated to 90°C for elevated operating temperatures
• VW-1 flame-retardant rating enhancing fire safety in installations
• 300V voltage rating suitable for standard control and signal circuits
**Applications**
• Suitable for data links in factory automation control cabinets
• Ideal for signal wiring in electrical panel assemblies
• Used with sensors and actuators requiring screened pair cables
• Can be used for machine-to-machine communications in mechanical systems
• Used for wiring in test and measurement benches
• Ideal for signal wiring in electrical panel assemblies
• Used with sensors and actuators requiring screened pair cables
• Can be used for machine-to-machine communications in mechanical systems
• Used for wiring in test and measurement benches
What materials comprise the conductors and how do they affect handling?
Conductors are tinned copper with seven strands per core, which improves flexibility for repetitive motion and eases termination while maintaining conductivity.
How is the cable screened and what does that provide?
Each paired assembly is wrapped and an overall aluminium/Mylar foil with a drain conductor is applied, offering predictable EMI rejection for sensitive signal lines.
What environmental resistances does the outer covering offer?
The outer jacket is PVC that provides sunlight resistance and a specified temperature range down to -30°C and up to 90°C for varied indoor and some outdoor exposures.
What mechanical limits should be observed during installation?
Minimum bend radius is ten times the cable diameter and maximum pull tension is 27 lb to avoid damage during routing and termination.
How is identification marked on the cable for traceability?
The sheath carries a printed product code and factory identifier along the jacket for inventory and installation tracking.
관련된 링크들
- Alpha Wire XTRA-GUARD 2 Series Data Cable, 1 Pairs, 30 m, Black Sheath Polyurethane
- Alpha Wire XTRA-GUARD 2 Series Data Cable, 4 Pairs, 30 m, Black Sheath Polyurethane
- Alpha Wire XTRA-GUARD 2 Series Data Cable, 3 Pairs, 30 m, Black Sheath Polyurethane
- Alpha Wire XTRA-GUARD 2 Series Data Cable, 2 Pairs, 30 m, Black Sheath Polyurethane
- Alpha Wire Xtra-Guard 2 Performance Cable Series Data Cable, 6 Pairs, 0.9 mm², 30 m, Black Sheath Thermoplastic
- Alpha Wire Xtra-Guard 2 Performance Cable Series Data Cable, 9 Pairs, 0.23 mm², 30 m, Black Sheath Thermoplastic
- Alpha Wire Xtra-Guard 2 Performance Cable Series Data Cable, 4 Pairs, 0.56 mm², 30 m, Black Sheath Thermoplastic
- Alpha Wire Xtra-Guard 2 Performance Cable Series Data Cable, 1 Pairs, 0.35 mm², 30 m, Black Sheath Thermoplastic