Omron H3YN Series Panel Timer Relay, 4-Contact, 125 V 100V ac, 120 V ac, 0.1 s to 10 min, Multifunction-Function, 4 NO/4
- RS 제품 번호:
- 106-6259
- 제조사 부품 번호:
- H3YN-4-B 100-120VAC
- 제조업체:
- Omron
Subtotal (1 unit)*
₩166,452.00
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량 | 한팩당 |
|---|---|
| 1 + | ₩166,452.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 106-6259
- 제조사 부품 번호:
- H3YN-4-B 100-120VAC
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Timer Relay | |
| Mount Type | Panel | |
| Time Range | 0.1 s to 10 min | |
| Number of Contacts | 4 | |
| Switching Voltage | 250V | |
| Number of Timer Functions | Multifunction | |
| Contact Configuration | 4 NO/4 NC | |
| IP Rating | IP40 | |
| Supply DC Voltage | 125 V | |
| Contact Current | 5A | |
| Minimum Operating Temperature | -10°C | |
| Supply AC Voltage | 100, 120V ac | |
| Maximum Operating Temperature | 55°C | |
| Terminal Type | Push-in | |
| Length | 21.5mm | |
| Height | 28mm | |
| Width | 56.6mm | |
| Standards/Approvals | CE, Lloyds, EN 61812-1, UL 508, CSA C22.2 No. 14, CCC, IEC 60664-1 | |
| Series | H3YN | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Timer Relay | ||
Mount Type Panel | ||
Time Range 0.1 s to 10 min | ||
Number of Contacts 4 | ||
Switching Voltage 250V | ||
Number of Timer Functions Multifunction | ||
Contact Configuration 4 NO/4 NC | ||
IP Rating IP40 | ||
Supply DC Voltage 125 V | ||
Contact Current 5A | ||
Minimum Operating Temperature -10°C | ||
Supply AC Voltage 100, 120V ac | ||
Maximum Operating Temperature 55°C | ||
Terminal Type Push-in | ||
Length 21.5mm | ||
Height 28mm | ||
Width 56.6mm | ||
Standards/Approvals CE, Lloyds, EN 61812-1, UL 508, CSA C22.2 No. 14, CCC, IEC 60664-1 | ||
Series H3YN | ||
- COO (Country of Origin):
- CN
Omron H3YN Series Timer Relay, 0.1s to 10min Time Range, 100/120V AC Supply Voltage - H3YN-4-B 100-120VAC
This multifunction timer relay provides selectable timing control for automated control panels and industrial equipment, delivering precise delay functions for sequence and process control in electrical and mechanical systems. It operates from an AC supply and is intended for panel mounting where Compact control timing and multiple contact outputs are required.
Features and Benefits:
• 4NO4NC contact arrangement offers simultaneous multi-circuit switching
• 5A contact rating allows direct control of moderate loads
• Time range 0.1s to 10 min enables fine-tuned process timing
• Push-in terminals permit rapid, tool-free wiring
• IP40 enclosure protection suits indoor control cabinet environments
• Multifunction operation supports diverse timing modes for flexibility
• 5A contact rating allows direct control of moderate loads
• Time range 0.1s to 10 min enables fine-tuned process timing
• Push-in terminals permit rapid, tool-free wiring
• IP40 enclosure protection suits indoor control cabinet environments
• Multifunction operation supports diverse timing modes for flexibility
Applications
• Suitable for sequence control in assembly-line automation
• Ideal for timed control of pneumatic and hydraulic valves
• Used with motor starters for delayed start or stop functions
• Can be used for staging lighting or signalling circuits in facilities
• Suitable for machine safety interlocks requiring timed actions
• Ideal for timed control of pneumatic and hydraulic valves
• Used with motor starters for delayed start or stop functions
• Can be used for staging lighting or signalling circuits in facilities
• Suitable for machine safety interlocks requiring timed actions
What supply voltages can it accept for operation?
It accepts 100/120V AC for the main supply and can be driven from 125V DC control supplies.
How does it handle temperature variations on site?
It is rated to operate between -10 °C and 55 °C, accommodating typical industrial ambient ranges.
How is the device mounted and secured within panels?
The unit is designed for panel mounting with a Compact form factor that slots into control enclosures.
What standards and approvals does it follow?
It meets a range of international standards and approvals including CE, UL508, CSA C22.2 No.14, IEC 60664-1 and CCC.
What is the expected switching capability in terms of voltage?
The contacts are rated for switching voltages up to 250V to manage common control and power circuits.
관련된 링크들
- Omron H3YN Series Timer Relay, 4-Contact, 100 to 120 V ac 100V ac, 120 V ac, 0.1 to 600 s, Multifunction-Function, 4PDT
- Omron H3YN Series Timer Relay, 4-Contact, 100 to 120 V ac 100V ac, 120 V ac, 0.1 to 600 min, Multifunction-Function,
- Omron H3YN Series Timer Relay, 4-Contact, 100 to 120 V ac 100V ac, 120 V ac, 0.1 to 600 s, Multifunction-Function, DPDT
- Omron H3YN Series Panel Timer Relay, 4-Contact, 125 V dc 100V ac, 120 V ac, 0.1 min to 10 h, Multifunction-Function, 4
- Omron H3YN Series Panel Timer Relay, 4-Contact, 125 V dc 100V ac, 120 V ac, 0.1 min to 10 h, Multifunction-Function,
- Omron H3YN Series Panel Timer Relay, 4-Contact, 125 V dc 100V ac, 120 V ac, 0.1 s to 10 min, Multifunction-Function,
- Omron H3YN Series Panel Timer Relay, 4-Contact, 125 V dc 200V ac, 230 V ac, 0.1 min to 10 h, Multifunction-Function, 4
- Omron H3YN Series Timer Relay, 4-Contact, 24 V dc 24V ac, 0.1 to 600 min, Multifunction-Function, 4PDT Switch
