Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 125 V dc 24V ac, 2 to 60 s, 1-Function, 4PDT Switch Configuration
- RS 제품 번호:
- 340-487
- 제조사 부품 번호:
- H3Y-4 AC24 60S
- 제조업체:
- Omron
대량 구매 할인 기용 가능
Subtotal (1 unit)*
₩102,687.00
재고있음
- 6 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 - 24 | ₩102,687.00 |
| 25 - 49 | ₩99,255.00 |
| 50 + | ₩95,959.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 340-487
- 제조사 부품 번호:
- H3Y-4 AC24 60S
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Timer Relay | |
| Mount Type | DIN Rail | |
| Function | Timer | |
| Time Range | 2 to 60 s | |
| Number of Contacts | 4 | |
| Number of Timer Functions | 1 | |
| Switching Voltage | 250V ac | |
| Contact Configuration | 4PDT | |
| IP Rating | IP40 | |
| Supply DC Voltage | 125 V dc | |
| Contact Current | 5A | |
| Minimum Operating Temperature | -10°C | |
| Supply AC Voltage | 24V ac | |
| Maximum Operating Temperature | 50°C | |
| Terminal Type | Plug-In | |
| Height | 63mm | |
| Length | 28mm | |
| Width | 21.5mm | |
| Standards/Approvals | IEC 60664-1, CCC:GB/T 14048.5, CSA C22.2 No. 14, UL 508, Lloyds, CE, EN 61812-1 | |
| Series | H3Y-4 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Timer Relay | ||
Mount Type DIN Rail | ||
Function Timer | ||
Time Range 2 to 60 s | ||
Number of Contacts 4 | ||
Number of Timer Functions 1 | ||
Switching Voltage 250V ac | ||
Contact Configuration 4PDT | ||
IP Rating IP40 | ||
Supply DC Voltage 125 V dc | ||
Contact Current 5A | ||
Minimum Operating Temperature -10°C | ||
Supply AC Voltage 24V ac | ||
Maximum Operating Temperature 50°C | ||
Terminal Type Plug-In | ||
Height 63mm | ||
Length 28mm | ||
Width 21.5mm | ||
Standards/Approvals IEC 60664-1, CCC:GB/T 14048.5, CSA C22.2 No. 14, UL 508, Lloyds, CE, EN 61812-1 | ||
Series H3Y-4 | ||
제외

Omron H3Y-4 Series Timer Relay, 24V AC Supply Voltage, 2 to 60s Time Range - H3Y-4 AC24 60S
This timer relay provides adjustable time-delay control for industrial automation and control panels, designed to switch circuits after a set interval within a 2 to 60 s range. It operates from a 24V AC supply and mounts on standard DIN-rail systems, offering multi-contact switching for sequential or delayed operations in electrical and mechanical installations.
Features and Benefits:
• Four changeover contacts enabling multi-circuit sequencing
• 5A contact rating supporting moderate load switching
• Plug-in terminals for Rapid installation and serviceability
• 250V AC switching capability for common control voltages
• Temperature tolerance from −10 °C to 50 °C for varied site conditions
• 5A contact rating supporting moderate load switching
• Plug-in terminals for Rapid installation and serviceability
• 250V AC switching capability for common control voltages
• Temperature tolerance from −10 °C to 50 °C for varied site conditions
Applications
• Suitable for staging motor start sequences in plant control panels
• Ideal for delay functions in conveyor and material-handling systems
• Used for timed control in HVAC and building-management circuits
• Can be used for interlock delays in safety and machinery systems
• Ideal for delay functions in conveyor and material-handling systems
• Used for timed control in HVAC and building-management circuits
• Can be used for interlock delays in safety and machinery systems
What mounting method does it use for panel integration?
It clips to a DIN rail to allow secure rail-mounted installation and easy replacement without panel rewiring.
How many independent switching points are available?
There are four changeover (4PDT) contacts permitting simultaneous control of multiple outputs.
Which approvals ensure it meets recognised manufacturing standards?
It conforms to a range of international standards including UL 508, IEC 60664-1, EN 61812-1, CCC and relevant certification bodies.
What Terminal style facilitates maintenance and wiring changes?
The plug-in Terminal arrangement allows Rapid withdrawal and reconnection for servicing or module swaps.
What environmental protection and operating limits apply?
The unit carries an IP40 enclosure rating and is specified for operation between −10 °C and 50 °C.
Approvals
UL, CSA
Standards
EN 50081-2, EN50082-2, VDE0435/P2021, VDE0110
관련된 링크들
- Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 125 V dc 24V ac, 2 to 60 s, 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 125 V dc 24V ac, 1 to 30 s, 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 125 V dc 24V ac, 1 to 30 min, 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 24 V dc 24V ac, 1 to 30 s, 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 125 V dc 24V ac, 0.2 to 5 min, 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 125 V dc 24V ac, 0.5 to 10 s, 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 125 V dc 24V ac, 0.1 to 3 min, 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 24 V dc 24V ac, 0.2 to 5 min, 1-Function, 4PDT Switch Configuration
