Schneider Electric TeSys GV3 Thermal Circuit Breaker - 3-Pole, Direct, 18 A Current Rating, 100 kA, 690 V ac

대량 구매 할인 기용 가능

Subtotal (1 unit)*

₩223,795.20

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 4월 03일 부터 12 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 - 5₩223,795.20
6 +₩219,320.80

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
272-892
제조사 부품 번호:
GV3P18
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Product Type

Thermal Circuit Breaker

Range

TeSys

Number of Poles

3

Series

GV3

Mount Type

Direct

Terminal Type

Screw

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Toggle Switch

Standards/Approvals

RoHS, CE

Depth

136mm

Height

160mm

Break Time

Medium

Breaking Capacity

100kA

Schneider Electric GV3 Series Thermal Circuit Breaker, 18A Current, 690V AC Rated AC Voltage - GV3P18


This thermal circuit-breaker provides thermal-magnetic motor protection for three-phase AC networks up to 690 V. Designed for use in control panels and DIN-rail systems, it interrupts fault currents and protects motors within its adjustable thermal range while allowing manual reset via a toggle-style actuator.

Features & Benefits


• 100 kA breaking capacity delivers high short-circuit interruption performance
• 12 to 18A thermal adjustment protects motors across load variations
• 18A conventional thermal current for continuous-duty applications
• 252A magnetic trip limits damage from high short-duration faults
• Screw terminals with EverLink compatibility ensure secure conductor connection

Applications


• Suitable for motor protection in industrial control panels
• Ideal for starters handling 7.5 kW to 15 kW motors depending on voltage
• used with contactor assemblies in automation installations
• Can be used for retrofit protection on 35mm DIN rails

What mounting options are available for installation?


It can be clipped onto 35mm symmetrical DIN rail or fastened to a panel using three M4 screws, allowing flexible mounting in cabinets or on equipment frames.

How does it perform under elevated ambient temperatures?


Thermal trip settings cover the 12 to 18A range to compensate for varying ambient conditions and maintain motor protection over the specified -20 to 60 °C operating range.

What mechanical and electrical life can be expected?


The device is rated for 50,000 mechanical cycles and 50,000 electrical cycles for AC-3 use at 415 V, supporting frequent switching in industrial environments.

Are there protection degrees and environmental tolerances to consider?


The enclosure meets IK09 impact resistance and provides IP20 protection

it also withstands storage from -40 to 80 °C and complies with the specified vibration and shock limits.

Standards

IEC 947 and UL 508 type E certification