Eaton 40A Tag Fuse 21 x 79 mm 500V

Subtotal (1 pack of 3 units)*

₩32,620.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 11월 18일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
팩
한팩당
한팩당*
1 +₩32,620.00₩10,874.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
261-580
제조사 부품 번호:
40NHG000BI NH FUSE 40A 500V SIZE 000 GG IMGL
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Current Rating

40A

Product Type

Tag Fuse

Fuse Size

21 x 79 mm

Voltage

500V

Standards/Approvals

DIN 43620, IEC 60269-2, IEC 60269-1

Application Category

Industrial, Solar Applications, Utilities, Wind

Fuse Speed

GG

High Rupture Capacity

Yes

Overall Length

79mm

Length

79mm

Width

21mm

Height

51mm

Series

Bussmann

제외

COO (Country of Origin):
IN

Eaton Tag Fuse, 40A Current Rating, 500V Voltage - 40NHG000BI NH FUSE 40A 500V SIZE 000 GG IMGL


This tag fuse provides overcurrent protection for industrial electrical systems, designed for use where high fault-current interruption is required. It is intended for installations in solar, wind and utility environments and is suitable for panel and switchgear applications that require a robust NH-format fuse capable of handling 500V systems.

Features and Benefits:


• 40A current rating gives predictable circuit protection under load
• Slow-blow GG characteristic mitigates inrush-related nuisance trips
• High rupture capacity allows interruption of large fault currents
• Complies with IEC 60269-2 for consistent performance across installations
• DIN43620-compatible format supports standard NH fuse holders
• Tag-style construction facilitates secure mounting and identification

Applications


• Suitable for protecting string inverters in solar installations
• Ideal for fault protection in wind turbine electrical cabinets
• Used with distribution equipment in utility substations
• Can be used for industrial motor control and feeder circuits

What voltage level is this device designed to operate at?


It is rated for use on systems up to 500V and intended for AC distribution applications where that voltage is present.

How does the slow-blow behaviour affect protection of equipment with startup currents?


The GG time-delay characteristic allows short-duration inrush currents to pass without opening while still clearing sustained overloads to protect conductors and devices.

Which standards ensure compatibility with common fuse infrastructure?


The product follows IEC60269-1 and IEC60269-2 requirements and fits DIN43620 physical mounting conventions for NH fuses.

What form factor and mounting considerations apply when replacing fuses?


The component uses the NH tag style and a 21x79mm link body that aligns with standard NH fuse holders for straightforward replacement.