Eaton 450A Tag Fuse 60 x 137 mm 660 V ac, 460V dc, 111 mm

Subtotal (1 unit)*

₩1,891,100.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2027년 7월 26일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩1,891,100.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
261-425
제조사 부품 번호:
TMF400M450
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Product Type

Tag Fuse

Fuse Type

TMF

Current Rating

450A

Fuse Size

60 x 137 mm

Voltage

660V ac, 460V ac

Standards/Approvals

No

Fixing Centres

111 mm

Application Category

gM

Tag Width

60mm

Fuse Characteristics

gM

Length

137mm

Overall Length

137mm

Width

60mm

Height

60mm

Series

Bussmann

COO (Country of Origin):
HU

Eaton Tag Fuse, 450A Current Rating, 60mm Width - TMF400M450


This tag fuse provides high-current circuit protection for industrial electrical systems, designed for insertion into switchgear and fuse holders. It is a centre-bolted tag device intended for general-purpose melting (gM) applications where robust isolation and interruption of fault currents are required in automation, electrical and mechanical installations.

Features and Benefits:


• 450A rating delivers high current protection for heavy circuits
• Compatible with 660V AC and 460V DC systems for versatile operation
• High rupture capacity supports fault clearing in switchgear
• Centre bolted tag allows reliable bolted connections
• 111mm fixing centres provide consistent mounting alignment

Applications


• Suitable for protecting incoming feeders in industrial switchgear
• Ideal for use in motor control and distribution panels
• Used with high-current cabling in manufacturing automation
• Can be used for DC plant protection in battery or traction systems

What physical form factor does it use for panel fitment?


The fuse is a tag style element with a 60mm tag width and a 137mm overall length to match tag fuse holders and mounting arrangements.

How does the tag connection affect installation torque and contact integrity?


Centre bolted tags concentrate clamping force at a central point, reducing uneven stress and improving electrical contact under high-current cycling.

Which fault regimes is it designed to interrupt?


It is specified for gM characteristic operation, meaning it will clear both overloads and short-circuit faults appropriate to heavy-duty distribution networks.

Can it replace other high-current tag fuses?


It is intended as a like-for-like replacement when dimensions, fixing centres and electrical ratings match the existing tag fuse requirements.

관련된 링크들