Eaton 20A Tag Fuse 21 x 79 mm 690V

Subtotal (1 pack of 3 units)*

₩33,384.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 10월 12일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
한팩당
한팩당*
1 +₩33,384.00₩11,128.65

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
251-347
제조사 부품 번호:
20NHG000B-690 NH FUSE 20A 690V SIZE 000 GG MGL
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Current Rating

20A

Product Type

Tag Fuse

Fuse Size

21 x 79 mm

Voltage

690V

Standards/Approvals

CE marked, RoHS Compliant, DIN 43620, IEC 60269-2, IEC 60269-1

Application Category

Wind, Industrial, Utilities, Solar Applications

Fuse Speed

GG

High Rupture Capacity

Yes

Overall Length

79mm

Length

79mm

Height

51mm

Width

21mm

Series

Eaton Bussmann

Eaton Tag Fuse, 20A Current Rating, 690V Voltage - 20NHG000B-690 NH FUSE 20A 690V SIZE 000 GG MGL


This tag fuse is a high-capacity protective device designed for use in industrial and renewable-energy electrical systems. It operates at elevated voltages and provides overcurrent interruption for circuits where slow response and high fault tolerance are required. The device is intended for panel and switchgear mounting in heavy-duty installations.

Features and Benefits:


• 20A rating delivers sustained circuit protection for prolonged loads
• 690V voltage capability permits use on high-voltage distribution networks
• GG slow-blow characteristic handles transient inrush without nuisance operation
• High rupture capacity interrupts severe short-circuits for system safety
• Compliant with recognised DIN and IEC formats ensures interchangeability

Applications


• Suitable for wind turbine electrical protection in nacelle and converter circuits
• Ideal for solar PV 690V DC arrays and string protection
• Used with industrial switchgear in manufacturing plants
• Can be used for utilities distribution feeders and substation protection
• Suitable for heavy-duty machinery requiring slow-blow overcurrent devices

What mounting format does it adopt for integration into switchgear?


It uses the standard NH/size000 tag format compatible with DIN-style fuse holders for inline installation in fuse blocks.

How does the slow-blow behaviour affect motor start-up protection?


The time-delay characteristic tolerates motor inrush currents, reducing unwanted fuse operation during normal starting cycles.

Which standards govern its rated performance and interchangeability?


Performance follows established IEC 60269 series and DIN 43620 dimensional references applicable to industrial fuses.

Is the product suitable for environments requiring restricted hazardous-arc handling?


Its high rupture capability is specified for interrupting high fault currents, mitigating energetic fault effects in heavy-duty systems.