Eaton 100A Tag Fuse 40 x 135 mm 500V

Subtotal (1 pack of 3 units)*

₩63,040.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2027년 3월 01일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
한팩당
한팩당*
1 +₩63,040.00₩21,014.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
243-492
제조사 부품 번호:
100NHG1B
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Product Type

Tag Fuse

Current Rating

100A

Fuse Size

40 x 135 mm

Voltage

500V

Standards/Approvals

DIN 43620, IEC 60269-2, IEC 60269-1

Application Category

Solar Applications, Wind, Industrial, Utilities

Fuse Speed

gL

High Rupture Capacity

Yes

Length

135mm

Overall Length

135mm

Height

63mm

Width

40mm

Series

100NHG1B

COO (Country of Origin):
IN

Eaton 100NHG1B Series Tag Fuse, 100A Current Rating, 500V Voltage - 100NHG1B


This tag fuse provides overcurrent protection for power distribution in renewable and industrial settings, designed for use in systems requiring Rapid interruption of fault currents. It operates as a high-capacity, NH-style protective element suitable for installations where reliable short-circuit clearance and compatibility with NH fuse holders are required.

Features and Benefits:


• 100A current rating enables protection of medium-current circuits
• 500V rated insulation supports high-voltage DC and AC systems
• gL fuse speed delivers fast-clearing performance for faults
• High rupture capacity prevents catastrophic failure under fault
• Complies with IEC60269-1 to maintain standardised interchangeability
• DIN43620 mounting profile ensures compatibility with NH holders

Applications


• Suitable for photovoltaic array string protection in PV systems
• Ideal for wind turbine internal distribution circuits
• Used with industrial switchgear for motor and feeder protection
• Can be used for utility sub-distribution and outgoing feeders
• Suitable for integration into automation control panels

What physical form factor does it use for panel installation?


The device is supplied in a 40x135mm NH fuse format compatible with standard NH fuse clips and holders.

How does its construction affect replacement selection?


Its high rupture capability and gL characteristic mean replacements must match both speed type and rupture rating to preserve fault-control performance.

Which standards are referenced for interchangeability and testing?


Compliance is with IEC60269-1 and DIN43620 which define dimensional, performance and testing criteria for NH fuses.

Is it suitable for both AC and DC service environments?


The voltage rating of 500V permits use across specified AC and DC systems within that maximum voltage.