SICK Female 8 way M12, Straight to Male 8 way M12, Straight Connector Cable, 15 m
- RS 제품 번호:
- 285-1414
- 제조사 부품 번호:
- YF2A18-150UA5M2A18 / 2104374
- 제조업체:
- SICK
Subtotal (1 unit)*
₩168,519.00
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량 | 한팩당 |
|---|---|
| 1 + | ₩168,519.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 285-1414
- 제조사 부품 번호:
- YF2A18-150UA5M2A18 / 2104374
- 제조업체:
- SICK
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | SICK | |
| Product Type | Connector Cable | |
| Series | YF2A18 | |
| Cable Length | 15m | |
| Jacket Colour | Black | |
| Jacket Material | Polyurethane | |
| Connector Gender A | Female | |
| Connector Type A | M12, Straight | |
| Number of Contacts A | 8 | |
| Number of Contacts B | 8 | |
| Connector Gender B | Male | |
| Connector Type B | M12, Straight | |
| Voltage | 30V ac/dc | |
| Standards/Approvals | IEC 60332-1, UL 1581 FT2 | |
| IP Rating | IP65, IP66K, IP67 | |
| Coding | A | |
| 모두 선택 | ||
|---|---|---|
브랜드 SICK | ||
Product Type Connector Cable | ||
Series YF2A18 | ||
Cable Length 15m | ||
Jacket Colour Black | ||
Jacket Material Polyurethane | ||
Connector Gender A Female | ||
Connector Type A M12, Straight | ||
Number of Contacts A 8 | ||
Number of Contacts B 8 | ||
Connector Gender B Male | ||
Connector Type B M12, Straight | ||
Voltage 30V ac/dc | ||
Standards/Approvals IEC 60332-1, UL 1581 FT2 | ||
IP Rating IP65, IP66K, IP67 | ||
Coding A | ||
- COO (Country of Origin):
- CZ
Sick YF2A18 Series Connector and Cable, 15m Cable Length, Polyurethane Jacket - YF2A18-150UA5M2A18 / 2104374
This connector and cable assembly provides a robust 8-contact link between sensors and actuators for industrial automation. It features straight M12 connectors at each end with gender-specific terminations to connect A-coded devices across a 15 m polyurethane-sheathed lead. The assembly is designed for use in demanding environments where sealed electrical connections and prolonged dynamic movement are required.
Features & Benefits
• IP65/IP66K/IP67 rating ensures protection against water ingress in harsh conditions
• Polyurethane black jacket resists oils and supports drag-chain use
• Rated for ≤30V AC/DC and 2A current loading for low-voltage control circuits
• 0.25mm² conductors provide consistent signal integrity for sensors
• Flexible operation down to −25 °C and stationary down to −40 °C for a wide temperature range
• Bending and torsion life supports 10,000,000 cycles and 2,000,000 torsion cycles
• Polyurethane black jacket resists oils and supports drag-chain use
• Rated for ≤30V AC/DC and 2A current loading for low-voltage control circuits
• 0.25mm² conductors provide consistent signal integrity for sensors
• Flexible operation down to −25 °C and stationary down to −40 °C for a wide temperature range
• Bending and torsion life supports 10,000,000 cycles and 2,000,000 torsion cycles
Applications
• Suitable for robot cabling requiring frequent motion and torsion
• Ideal for sensor to actuator interfaces in automated production lines
• used with equipment in zones exposed to oils and lubricants
• Can be used for drag-chain installations with repeated travel
• Suitable for low-voltage control wiring in electrical cabinets
• Ideal for sensor to actuator interfaces in automated production lines
• used with equipment in zones exposed to oils and lubricants
• Can be used for drag-chain installations with repeated travel
• Suitable for low-voltage control wiring in electrical cabinets
How are the connectors secured and assembled to mating devices?
The connectors use screw locking with a zinc die-cast nickel-plated nut tightened to 0.6 N·m and a 13mm width across flats for mechanical retention.
What mechanical movement specifications support use on moving machinery?
The cable tolerates traversing speeds up to 3 m/s, travelling distances up to 10 m, and accelerations up to 10 m/s² to suit dynamic installations.
Is the cable shielded and what is its conductor arrangement?
The lead is unshielded and contains eight individual conductors with a 0.25mm² cross-section
note that wire-colour assignments are not standardised so pin mapping must be checked.
What thermal and flame behaviour applies to the cable materials?
The jacket meets flame tests such as UL 1581 horisontal and CSA FT2 and complies with IEC 60332-1 and IEC 60332-2-2 standards for limited flame propagation.
What operating approvals and environmental ratings does it carry?
It holds UL authorisation under file E335179, an ambient head temperature range up to +85 °C, and contamination rating 3 for industrial conditions.
관련된 링크들
- SICK Female 8 way M12, Straight to Male 8 way M12, Straight Connector Cable, 3 m
- SICK Female 8 way M12, Straight to Male 8 way M12, Straight Connector Cable, 1 m
- SICK Female 8 way M12, Straight to Male 4 way M12, Straight Connector Cable, 5 m
- SICK Female 8 way M12, Straight to Male 4 way M12, Straight Connector Cable, 2 m
- SICK Female 8 way M12, Straight to Male 4 way M12, Straight Connector Cable, 2.5 m
- SICK Female 8 way M12, Straight to Male 4 way M12, Straight Connector Cable, 1.5 m
- SICK Female 8 way M12, Straight to Male 4 way Straight M12 Connector Cable, 3 m
- SICK Female 8 way M12, Straight to Male 4 way Straight M12 Connector Cable, 1 m