Phoenix Contact PSR-SPP-24DC/URD3/4X1/2X2/3, 24V dc Safety Relay, 6 Safety Contacts

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

Subtotal (1 unit)*

₩594,620.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2027년 1월 11일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩594,620.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
666-7066
제조사 부품 번호:
2981745
제조업체:
Phoenix Contact
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Phoenix Contact

Product Type

Safety Relay

Safety Contacts

6

Mount Type

DIN Rail

Series

PSR-SPP-24DC/URD3/4X1/2X2/3

Terminal Type

Screw

IP Rating

IP54

Minimum Operating Temperature

-20°C

Standards/Approvals

IEC, RoHS

Switching AC Voltage

250V ac

Contact Current

94mA

Switching DC Voltage

250V dc

Maximum Operating Temperature

55°C

Length

112mm

Height

114.5mm

Width

22.5mm

Safety Category

3

Hazardous Area Certification

No

Coil Voltage

24V dc

COO (Country of Origin):
DE

Multi-application Modular System - PSR Series


The PSR safety relays from Phoenix contacts can be quickly and reliably assembled to form a tailor-made safety solution.

To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection.

Features and Benefits


• Quick system extension up to 10 modules, offering a safety system with up to 42 contacts

• Automatic identification of desired operating mode, no need to set switches or define parameters

• The system is based on a master relay (PSR-SDC) that monitors e-stops, guard doors (interlock or non-contact) and optical devices (e.g. light curtains)

• Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple

• 24Vdc supply voltage

• Semiconductor output

• Depending on the wiring Safety category 2 or 4 can be maintained

• One or Two channel switches are used for control

Note

The device has a rear interface for the DIN Rail connector T-BUS. Via this T-BUS interface extension devices PSR-URM4-B (undelayed contacts) and PSR-URD (drop-out delay contacts) can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final (right hand) extension device (see datasheet for more details) or by using connection plug PSR-TBUS-TP.

관련된 링크들