Eaton RCD, 10A, 2 Pole, 30mA, Type C, 230V
- RS 제품 번호:
- 922-8715
- 제조사 부품 번호:
- 236082 PKNM-10/1N/C/003-A-MW
- 제조업체:
- Eaton
Subtotal (1 unit)*
₩209,356.80
재고있음
- 14 개 단위 배송 준비 완료
- 추가로 2026년 2월 17일 부터 165 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩209,356.80 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 922-8715
- 제조사 부품 번호:
- 236082 PKNM-10/1N/C/003-A-MW
- 제조업체:
- Eaton
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Eaton | |
| Circuit Breaker Type | RCD | |
| Current Rating | 10A | |
| Number of Poles | 2 | |
| Range | PKNM | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Voltage Rating | 230V | |
| Standards Met | CE | |
| Terminal Contact Type | Screw | |
| Overall Width | 65.5mm | |
| Earth Leakage Protection Type | A | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Rated AC Voltage | 230V | |
| Mounting Style | DIN Rail Mount | |
| Break Time | Instantaneous | |
| Reset Actuator Type | Toggle Switch | |
| Overall Depth | 80mm | |
| Overall Length | 35mm | |
| Overall Dimensions | 35 x 65.5 x 80mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Eaton | ||
Circuit Breaker Type RCD | ||
Current Rating 10A | ||
Number of Poles 2 | ||
Range PKNM | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Voltage Rating 230V | ||
Standards Met CE | ||
Terminal Contact Type Screw | ||
Overall Width 65.5mm | ||
Earth Leakage Protection Type A | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Rated AC Voltage 230V | ||
Mounting Style DIN Rail Mount | ||
Break Time Instantaneous | ||
Reset Actuator Type Toggle Switch | ||
Overall Depth 80mm | ||
Overall Length 35mm | ||
Overall Dimensions 35 x 65.5 x 80mm | ||
- COO (Country of Origin):
- RO
Eaton RCD, Screw Terminals, Front Toggle Switch - PKNM Series - 236082 PKNM-10/1N/C/003-A-MW
Keep your people safe from electric shocks with this RCD from Eaton. Its type-C tripping characteristics make it suitable for protecting more powerful motors. If the current exceeds two to five times the rated load, the unit will trip and shut off the power before any damage can be done. Once you've found and rectified the fault, simply flick the toggle switch to reset the RCD and get up and running again.
Features & Benefits
• Screw terminals help you quickly make secure electrical connections
• Red and green contact position indicators let you check the status at a glance
• Single-pole plus neutral configuration means it protects both the phase and neutral conductors in single-phase loads such as lighting
• 10A current rating to protect circuits with the same input
• Red and green contact position indicators let you check the status at a glance
• Single-pole plus neutral configuration means it protects both the phase and neutral conductors in single-phase loads such as lighting
• 10A current rating to protect circuits with the same input
What's the difference between an RCD and an MCB?
An RCD (residual current device) is a safety device that detects and disconnects power when it senses a leakage of current. An MCB (miniature circuit breaker) is designed to protect circuits from overcurrents and short circuits by interrupting the flow of current. While both enhance electrical safety, an RCD focuses on keeping people safe rather than protecting the circuit.
Note
Eaton formerly known as Moeller
관련된 링크들
- Eaton RCD, 6A, 2 Pole, 30mA, Type C, 230V
- Eaton RCD, 20A, 2 Pole, 30mA, Type C, 230V
- Eaton RCD, 25A, 2 Pole, 30mA, Type C, 230V
- Eaton RCD, 10A, 2 Pole, 30mA, Type B, 230V ac
- Eaton RCD, 10A, 2 Pole, 30mA, Type C
- Eaton RCD, 25A, 2 Pole, 30mA, Type B, 230V
- Eaton RCD, 16A, 2 Pole, 30mA, Type B, 230V
- Eaton PKN6/M RCD, 6A, 2 Pole, 30mA, Type C, 230V ac