Eaton PFIM RCD, 16A, 2 Pole, 30mA, Type A, 230V ac
- RS 제품 번호:
- 922-8648
- 제조사 부품 번호:
- 235423 PFIM-16/2/003-A-MW
- 제조업체:
- Eaton
Subtotal (1 unit)*
₩220,749.60
재고있음
- 3 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩220,749.60 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 922-8648
- 제조사 부품 번호:
- 235423 PFIM-16/2/003-A-MW
- 제조업체:
- Eaton
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Eaton | |
| Circuit Breaker Type | RCD | |
| Current Rating | 16A | |
| Number of Poles | 2 | |
| Range | PFIM | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type A | |
| Voltage Rating | 230V ac | |
| Series | PFIM | |
| Standards Met | IEC/EN 61008 | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Overall Length | 76mm | |
| Reset Actuator Type | Toggle Switch | |
| Earth Leakage Protection Type | A | |
| Terminal Contact Type | Screw | |
| Overall Width | 35mm | |
| Application | Commercial, Residential | |
| Overall Dimensions | 35 x 65.5 x 80mm | |
| Break Time | Instantaneous | |
| Overall Depth | 80mm | |
| Rated AC Voltage | 230, 400V | |
| Mounting Style | DIN Rail Mount | |
| 모두 선택 | ||
|---|---|---|
브랜드 Eaton | ||
Circuit Breaker Type RCD | ||
Current Rating 16A | ||
Number of Poles 2 | ||
Range PFIM | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type A | ||
Voltage Rating 230V ac | ||
Series PFIM | ||
Standards Met IEC/EN 61008 | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Overall Length 76mm | ||
Reset Actuator Type Toggle Switch | ||
Earth Leakage Protection Type A | ||
Terminal Contact Type Screw | ||
Overall Width 35mm | ||
Application Commercial, Residential | ||
Overall Dimensions 35 x 65.5 x 80mm | ||
Break Time Instantaneous | ||
Overall Depth 80mm | ||
Rated AC Voltage 230, 400V | ||
Mounting Style DIN Rail Mount | ||
Eaton PFIM Series RCD, 16A Current Rating, 30mA Trip Sensitivity - 235423 PFIM-16/2/003-A-MW
This residual current device (RCD) provides essential earth leakage protection for commercial and residential applications. Designed for mounting on a DIN rail, the device features a robust, compact design measuring 35 x 76 x 80 mm. Compliant with IEC/EN 61008 standards, it effectively trips at a sensitivity of 30mA, ensuring safety without compromising functionality.
Features & Benefits
• Instantaneous break time enhances user safety during faults
• Type A RCD breaker protects against earth leakage currents
• Rated current of 16A suits a variety of electrical installations
• 2-pole configuration allows for versatile circuit applications
• Capable of withstanding breaking capacity of 10kA
• Easily mounted on standard DIN rails for convenience
• Type A RCD breaker protects against earth leakage currents
• Rated current of 16A suits a variety of electrical installations
• 2-pole configuration allows for versatile circuit applications
• Capable of withstanding breaking capacity of 10kA
• Easily mounted on standard DIN rails for convenience
Applications
• Used for protection in residential electrical systems
• Ideal for commercial installations requiring reliable earth fault protection
• Can be used in functions effectively in various voltage up to 400V
• Ideal for commercial installations requiring reliable earth fault protection
• Can be used in functions effectively in various voltage up to 400V
How does the earth leakage protection function in this device?
Earth leakage protection is achieved through a sensitive trip mechanism that detects imbalance between live and neutral currents, tripping the circuit to prevent electric shocks. The 30mA sensitivity provides suitable protection for both residential and commercial environments.
What are the temperature specifications for using this device?
The device is rated for operation in ambient temperatures ranging from -25°C to 55°C, which ensures efficiency in diverse environmental conditions. It's important to note that continuous current capability decreases by 3% for each degree above 40°C.
Can this RCD be integrated with other devices in a switchboard?
Yes, it can be easily integrated with other electrical devices, as it supports selective protection and a range of additional equipment. Proper installation should be followed according to manufacturer guidelines for optimal performance.
Note
Eaton formerly known as Moeller
관련된 링크들
- Eaton PFIM RCD, 63A, 4 Pole, 30mA, Type AC, 230V ac
- Eaton PFIM RCD, 25A, 4 Pole, 30mA, Type AC, 400V ac
- Eaton RCD, 63A, 2 Pole, 30mA, Type AC, 230V
- Eaton RCD, 40A, 2 Pole, 30mA, Type A, 230V ac
- Eaton RCD, 25A, 2 Pole, 30mA, Type A
- Eaton RCD, 25A, 2 Pole, 30mA, Type G
- Eaton RCD, 40A, 4 Pole, 30mA, Type A, 230/400V ac
- Eaton RCD, 25A, 4 Pole, 30mA, Type A