ABB FH200 Series Residual Current Circuit Breaker, 40A, 2-Pole, 30 mA, Type A, 1 kA 230V ac
- RS 제품 번호:
- 186-3459
- 제조사 부품 번호:
- 2CSF202102R1400
- 제조업체:
- ABB
Subtotal (1 unit)*
₩115,674.00
일시적 품절
- 2026년 7월 14일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩115,674.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 186-3459
- 제조사 부품 번호:
- 2CSF202102R1400
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40A | |
| Number of Poles | 2 | |
| Series | FH200 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type A | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw | |
| Standards/Approvals | CE | |
| Height | 85mm | |
| Depth | 69mm | |
| Width | 35mm | |
| Breaking Capacity | 1kA | |
| Break Time | Instantaneous | |
| Rated AC Voltage | 230V ac | |
| Earth Leakage Protection Type | Type A | |
| Application | Domestic | |
| Tripping Mechanism | Electromagnetic | |
| Reset Actuator Type | Toggle Switch | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40A | ||
Number of Poles 2 | ||
Series FH200 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type A | ||
Mount Type DIN Rail | ||
Terminal Type Screw | ||
Standards/Approvals CE | ||
Height 85mm | ||
Depth 69mm | ||
Width 35mm | ||
Breaking Capacity 1kA | ||
Break Time Instantaneous | ||
Rated AC Voltage 230V ac | ||
Earth Leakage Protection Type Type A | ||
Application Domestic | ||
Tripping Mechanism Electromagnetic | ||
Reset Actuator Type Toggle Switch | ||
ABB RCCB, Instantaneous Tripping Type, 4kV Impulse Withstand Voltage - FH200 Series - 2CSF202102R1400
To stop faulty currents in their tracks, add an extra layer of protection with this RCCB from ABB. It monitors the flow of incoming and outgoing current, quickly cutting off the power if it senses any leakage. This helps to protect users from electric shocks and reduces the risk of fire. A front-facing toggle switch lets you swiftly reset it after it trips. As this switch features contact indicators, status-checking is a cinch. With a broad operating temperature range between -5°C and +40°C, this versatile unit suits domestic, commercial and industrial environments.
Features & Benefits
• Integrated test button for easy troubleshooting
• 4kV rated impulse withstand voltage provides enhanced protection against transient overvoltage
• Instantaneous break time for rapid power disconnection and maximised safety during fault conditions
Applications
• Construction sites
• Security devices
• Machine tools
• HVAC systems
What's meant by this RCCB's type-A tripping characteristic?
The Type A characteristic of this RCCB ensures instantaneous tripping for residual AC and pulsating DC.
How do I mount this RCCB?
It simply clips onto a DIN rail, so there's no need to reach for your tools.
관련된 링크들
- ABB FH200 Series Residual Current Circuit Breaker, 63A, 2-Pole, 30 mA, Type A, 1 kA 230V ac
- ABB FH200 Series Residual Current Circuit Breaker, 40A, 2-Pole, 30 mA, Type A, 1 kA 230V ac
- ABB FH200 Series Residual Current Circuit Breaker, 40A, 2-Pole, 30 mA, Type AC, 1 kA 230V ac
- ABB FH200 Series Residual Current Circuit Breaker, 40A, 4-Pole, 30 mA, Type A, 1 kA 400V ac
- ABB FH200 Series Residual Current Circuit Breaker, 25A, 2-Pole, 30 mA, Type AC, 1 kA 230V ac
- ABB FH200 Series Residual Current Circuit Breaker, 63A, 2-Pole, 30 mA, Type AC, 1 kA 230V ac
- ABB FH200 Series Residual Current Circuit Breaker, 40A, 2-Pole, 30 mA, Type AC, 0.03 A 400V ac