ABB F200 RCCB, 25A, 4 Pole, 30mA, 400V ac
- RS 제품 번호:
- 176-9635
- Distrelec 제품 번호:
- 300-76-730
- 제조사 부품 번호:
- 2CSF204325R1250 F204 F-25/0,03
- 제조업체:
- ABB
Subtotal (1 unit)*
₩975,838.44
일시적 품절
- 2026년 5월 25일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩975,838.44 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 176-9635
- Distrelec 제품 번호:
- 300-76-730
- 제조사 부품 번호:
- 2CSF204325R1250 F204 F-25/0,03
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Circuit Breaker Type | RCCB | |
| Current Rating | 25A | |
| Number of Poles | 4 | |
| Trip Sensitivity | 30mA | |
| Voltage Rating | 400V ac | |
| Series | F200 | |
| Earth Leakage Protection Type | A-APR | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Overall Depth | 85mm | |
| Break Time | Time Delay | |
| Overall Length | 70mm | |
| Terminal Contact Type | Screw | |
| Overall Dimensions | 70 x 69 x 85mm | |
| Reset Actuator Type | Toggle Switch | |
| Overall Width | 69mm | |
| Special Features | Earth Fault Safety Protection | |
| Mounting Style | DIN Rail Mount | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Circuit Breaker Type RCCB | ||
Current Rating 25A | ||
Number of Poles 4 | ||
Trip Sensitivity 30mA | ||
Voltage Rating 400V ac | ||
Series F200 | ||
Earth Leakage Protection Type A-APR | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Overall Depth 85mm | ||
Break Time Time Delay | ||
Overall Length 70mm | ||
Terminal Contact Type Screw | ||
Overall Dimensions 70 x 69 x 85mm | ||
Reset Actuator Type Toggle Switch | ||
Overall Width 69mm | ||
Special Features Earth Fault Safety Protection | ||
Mounting Style DIN Rail Mount | ||
- COO (Country of Origin):
- IT
F204 Type F, RCCB in four poles with rated current 25-40-63A and sensitivity 30mA for the protection of more than one single phase circuit with a single device.
Type F features at a glance:
Type F RCDs offer the same range of protection and functionality as an RCD Type A APR
this means that they detect sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are also tested according to IEC/EN 62423 which foresees the application of a simulated multi-frequency residual current with appropriate coefficient associated to the each level of frequency up to 1kHz.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.
관련된 링크들
- ABB F200 RCCB, 63A, 4 Pole, 30mA, 400V ac
- ABB F200 RCCB, 25A, 4 Pole, 30mA, Type AC
- ABB F200 RCCB, 25A, 4 Pole, 30mA, Type A, 230/400V ac
- ABB FH200 RCCB, 25A, 4 Pole, 30mA, Type AC
- ABB F200 RCCB, 25A, 4 Pole, 30mA, Type A, 110V ac
- ABB RCCB, 40A, 4 Pole
- ABB F200 RCCB, 25A, 2 Pole, 30mA, Type AC, 230V
- ABB F200 RCCB, 25A, 2 Pole, 30mA, Type A, 230/400V ac