Eaton xEffect Series Residual Current Circuit Breaker, 16 A, 4-Pole, 300 mA, Type F, 500 A 415 V ac

Subtotal (1 unit)*

₩601,581.20

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 4월 27일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩601,581.20

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
246-778
제조사 부품 번호:
187437 FRCMM-16/4/03-S/F
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Product Type

Residual Current Circuit Breaker

Current Rating

16 A

Number of Poles

4

Series

xEffect

Range

FRCmM

Trip Sensitivity

300mA

Mount Type

DIN Rail

Tripping Characteristics

Type F

Standards/Approvals

IEC/EN 62423 EN45545-2 IEC 61373 IEC/EN 61008

Terminal Type

Twin-Purpose Terminal

Width

70 mm

Height

80mm

Depth

76mm

Breaking Capacity

500A

Earth Leakage Protection Type

F

Rated AC Voltage

415 V ac

Break Time

40 ms

Tripping Mechanism

Residual Current

COO (Country of Origin):
RS
The Eaton residual current circuit breaker represents the pinnacle of reliability and safety in electrical installations. Designed for industrial and advanced commercial applications, it effectively safeguards against electrical faults, ensuring peace of mind in operations. With its four-pole configuration and sensitivity to leakage currents, this device is engineered to provide optimal protection where it’s needed most. Its robust design and adaptability make it a versatile choice for a range of environments, while its compact dimensions allow for easy integration into existing systems. The product boasts impressive technical specifications, such as high fault current ratings and rapid tripping times, reinforcing its status as a trusted solution in critical settings. Experience enhanced operational safety with a device that meets rigorous compliance standards and operates efficiently under various conditions.

Delivers reliable protection in commercial and industrial settings

Compact design allows for seamless installation in confined spaces

Offers rapid tripping time for quick response to electrical faults

Meets stringent compliance certifications for utmost safety assurance

Features pulse-current sensitivity for enhanced fault detection

Suitable for a wide range of operational voltages

Constructed with high-quality materials to withstand environmental challenges

Incorporates dual terminals for flexible wiring options

Enables easy maintenance with accessible design and indicators

Supports a diverse array of conductor cross-sections for versatility