Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 100 mA Trip

Subtotal (1 unit)*

₩282,660.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 03일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩282,660.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
790-9298
제조사 부품 번호:
A9D12816
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Product Type

Residual Current Circuit Breaker with Overload Protection

Current Rating

16A

Number of Poles

1

Series

iC60H

Range

Acti9

Trip Sensitivity

100mA

Tripping Characteristics

B Curve, D Curve, Type A, C Curve

Mount Type

DIN Rail

Rated AC Voltage

230V ac

Terminal Type

Screw Clamp

Earth Leakage Protection Type

Type A

Width

18mm

Depth

77.5mm

Application

Industrial Isolation

Breaking Capacity

10kA

Standards/Approvals

BS/EN 60898-1, BS/EN 60947-2, BS EN 61009-1, BS EN 61439-3

Schneider Electric iC60H Series RCBO, 16A Current Rating, DIN Rail Mount - A9D12816


This residual current circuit breaker with overcurrent protection (RCBO) is designed for consistent performance in electrical distribution applications. The compact dimensions of 18x110x77.5mm enable easy installation on DIN rail systems. With a rated current of 16A and a trip sensitivity of 100mA, this device ensures safe operation in various environments.

Features & Benefits


• 1P+N configuration enhances versatility in usage

• Type A earth leakage protection offers effective safety

• Screw clamp terminals facilitate secure wire connections

• Instantaneous earth-leakage protection reduces fault response time

• Thermal-magnetic trip unit technology provides dependable performance

• Green Premium certification signifies eco-friendly standards

Applications


• Used for residential and commercial electrical installations

• Suitable for protecting sensitive electronic equipment

• Appropriate for circuits requiring earth leakage protection

• Utilised in automation and mechanical systems

Can it handle electrical faults effectively?


Yes, it provides effective protection against electrical faults.

Is it compatible with standard DIN rail systems?


Yes, the product is designed for DIN rail mounting.

Will it indicate the status of current flow?


Yes, it features local signalling for ON/OFF indication.

Does it have provisions for isolation?


Yes, it is suitable for isolation in electrical systems.

Can it operate in varying temperature conditions?


Yes, it functions between -15°C and 60°C ambient temperature.

관련된 링크들