Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip

Subtotal (1 unit)*

₩310,108.50

Add to Basket
수량 선택 또는 입력
재고있음
  • 162 개 단위 배송 준비 완료
  • 추가로 2026년 7월 10일 부터 27 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩310,108.50

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
790-9294
Distrelec 제품 번호:
304-02-120
제조사 부품 번호:
A9D11816
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Current Rating

16A

Product Type

Residual Current Circuit Breaker with Overload Protection

Series

Acti9

Range

Acti9

Number of Poles

1

Trip Sensitivity

30mA

Tripping Characteristics

Type C

Mount Type

DIN Rail

Rated AC Voltage

240V ac

Terminal Type

Screw

Earth Leakage Protection Type

Type A

Width

18mm

Depth

77.5mm

Height

110mm

Application

Distribution

Breaking Capacity

10kA

Tripping Mechanism

Thermal Magnetic

Standards/Approvals

IEC

Schneider Electric RCBO, 1P+N Configuration, Thermal-Magnetic Tripping Mechanism - iC60H Series - A9D11816


Use this RCBO from Schneider Electric to make sure there's nothing that can shock you in your electrical installation. It's an essential bit of kit that uses a thermal-magnetic mechanism to safeguard people and equipment against residual currents and overloads. Thanks to 30mA earth-leakage sensitivity and instantaneous tripping, it minimises contact with harmful currents. The device is designed with a one-pole plus neutral configuration, making it useful for protecting final distribution circuits in TN earthing systems.

Features & Benefits


• Toggle switch for easy manual operation

• Easy-to-read on/off indicator means there's no confusion when you're carrying out work or resetting the device

• Can be padlocked to keep you safe when you're carrying out electrical work

• Works reliably in temperatures between -15°C and +60°C, making it handy for commercial and industrial environments

• Insulated terminals help the device achieve an IP20 rating, so it's touch-safe

Applications


• Residential buildings

• Offices

• Medical centres

What causes earth-leakage currents?


Earth leakage currents can occur when there are breaks or errors in your wiring circuit. Faulty appliances and incorrect equipment installation are two common causes.

Schneider Electric Acti9 iC60H RCBOs Range


iC60H RCBO carries out complete protection of final circuits:

  • Protection against short-circuits and cable overloads

  • Protection of persons against electric shock by direct contact (10, 30 mA sensitivities)

  • Protection of persons against electric shock by indirect contact (100 mA sensitivity)

  • Protection of equipment against fires set by leakage currents (100 mA sensitivity)

  • 관련된 링크들