Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 2-Pole, 30 mA Trip

Subtotal (1 unit)*

₩417,183.00

Add to Basket
수량 선택 또는 입력
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량
한팩당
1 +₩417,183.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
790-9254
제조사 부품 번호:
A9D11225
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Product Type

Residual Current Circuit Breaker with Overload Protection

Current Rating

25A

Number of Poles

2

Range

Acti9

Series

iC60H

Trip Sensitivity

30mA

Tripping Characteristics

C Curve, D Curve, B Curve

Mount Type

DIN Rail

Rated AC Voltage

415V ac

Earth Leakage Protection Type

Type A

Application

Industrial Isolation

Standards/Approvals

BS/EN 60898-1, BS/EN 60947-2, BS EN 61009-1, BS EN 61439-3

Breaking Capacity

10kA

Schneider Electric iC60H2 Series RCBO, 2P, Current Rating 25A - A9D11225


This device operates as a residual current circuit breaker with overcurrent protection, designed for effective electrical distribution. It features a thermal-magnetic tripping mechanism along with earth leakage protection, safeguarding electrical installations against faults and ensuring the safety of both equipment and personnel. Its compact design is suited for DIN rail mounting, facilitating seamless integration into existing systems and positioning it as a crucial element in modern electrical setups.

Features & Benefits


• Provides 30mA earth leakage protection to enhance safety

• Delivers a 10kA breaking capacity for effective response to faults

• Employs thermal-magnetic technology for reliable tripping performance

• Compact form factor simplifies DIN rail installation

• Compatible with various earthing systems for versatile applications

• Enables instantaneous earth leakage protection for quick response

Applications


• Used in industrial and commercial electrical distribution systems

• Suitable for circuits needing reliable earth leakage protection

• Commonly found in residential settings to enhance safety measures

• Applied in automation systems to guard against electrical faults

What is the process for installing this device?


The device is designed for DIN rail mounting, which simplifies integration into existing electrical panels.

Can it be used with various earthing systems?


Yes, it accommodates IT, TN, and TT earthing systems, providing flexibility for different installations.

How frequently should maintenance be performed?


Regular inspections are recommended approximately every six months to ensure optimal function and safety.

What occurs during an earth fault?


If an earth fault is detected, the device will trip to disconnect the circuit, preventing electrical shocks and protecting equipment from damage.

Is it suitable for outdoor applications?


No, this device is intended for indoor use only, as it has an IP20 protection rating.