Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 2-Pole, 30 mA Trip
- RS 제품 번호:
- 790-9254
- 제조사 부품 번호:
- A9D11225
- 제조업체:
- Schneider Electric
Subtotal (1 unit)*
₩417,183.00
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량 | 한팩당 |
|---|---|
| 1 + | ₩417,183.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 790-9254
- 제조사 부품 번호:
- A9D11225
- 제조업체:
- Schneider Electric
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 25A | |
| Number of Poles | 2 | |
| Range | Acti9 | |
| Series | iC60H | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | C Curve, D Curve, B Curve | |
| Mount Type | DIN Rail | |
| Rated AC Voltage | 415V ac | |
| Earth Leakage Protection Type | Type A | |
| Application | Industrial Isolation | |
| Standards/Approvals | BS/EN 60898-1, BS/EN 60947-2, BS EN 61009-1, BS EN 61439-3 | |
| Breaking Capacity | 10kA | |
| 모두 선택 | ||
|---|---|---|
브랜드 Schneider Electric | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 25A | ||
Number of Poles 2 | ||
Range Acti9 | ||
Series iC60H | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics C Curve, D Curve, B Curve | ||
Mount Type DIN Rail | ||
Rated AC Voltage 415V ac | ||
Earth Leakage Protection Type Type A | ||
Application Industrial Isolation | ||
Standards/Approvals BS/EN 60898-1, BS/EN 60947-2, BS EN 61009-1, BS EN 61439-3 | ||
Breaking Capacity 10kA | ||
Schneider Electric iC60H2 Series RCBO, 2P, Current Rating 25A - A9D11225
This device operates as a residual current circuit breaker with overcurrent protection, designed for effective electrical distribution. It features a thermal-magnetic tripping mechanism along with earth leakage protection, safeguarding electrical installations against faults and ensuring the safety of both equipment and personnel. Its compact design is suited for DIN rail mounting, facilitating seamless integration into existing systems and positioning it as a crucial element in modern electrical setups.
Features & Benefits
• Provides 30mA earth leakage protection to enhance safety
• Delivers a 10kA breaking capacity for effective response to faults
• Employs thermal-magnetic technology for reliable tripping performance
• Compact form factor simplifies DIN rail installation
• Compatible with various earthing systems for versatile applications
• Enables instantaneous earth leakage protection for quick response
Applications
• Used in industrial and commercial electrical distribution systems
• Suitable for circuits needing reliable earth leakage protection
• Commonly found in residential settings to enhance safety measures
• Applied in automation systems to guard against electrical faults
What is the process for installing this device?
The device is designed for DIN rail mounting, which simplifies integration into existing electrical panels.
Can it be used with various earthing systems?
Yes, it accommodates IT, TN, and TT earthing systems, providing flexibility for different installations.
How frequently should maintenance be performed?
Regular inspections are recommended approximately every six months to ensure optimal function and safety.
What occurs during an earth fault?
If an earth fault is detected, the device will trip to disconnect the circuit, preventing electrical shocks and protecting equipment from damage.
Is it suitable for outdoor applications?
No, this device is intended for indoor use only, as it has an IP20 protection rating.
관련된 링크들
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 20A Current Rating, 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 40A Current Rating, 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 32A Current Rating, 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 1-Pole, 25000 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 16000 mA Trip