Schneider Electric Residual Current Circuit Breaker with Overload Protection, 20A Current Rating, 1-Pole, 30 mA Trip

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

Subtotal (1 unit)*

₩273,702.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 26 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩273,702.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
790-9213
제조사 부품 번호:
A9D31820
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Product Type

Residual Current Circuit Breaker with Overload Protection

Current Rating

20A

Series

Acti9

Number of Poles

1

Range

Acti9

Trip Sensitivity

30mA

Tripping Characteristics

Type B

Mount Type

DIN Rail

Rated AC Voltage

240V ac

Terminal Type

Screw

Earth Leakage Protection Type

Type A

Width

18mm

Depth

77.5mm

Height

110mm

Standards/Approvals

IEC

Tripping Mechanism

Thermal Magnetic

Application

Distribution

Breaking Capacity

10kA

Schneider Electric RCBO, 30mA Trip Sensitivity, Integrated Earth Leakage Protection - Acti9 Series - A9D31820


Put a stopper in harmful leakage currents with this RCBO from Schneider Electric. The unit has a 30mA trip sensitivity, so when there's a change in the residual current it takes only a few milliseconds to trip. This speedy response provides a high level of protection against harmful electrical faults, which could otherwise cause fires, electric shocks and equipment damage. As the screw terminals are located beyond the reach of your fingers, there's no risk of you touching live parts.

Features & Benefits


• Broad operating temperature range between -15°C and +60°C for use in challenging conditions

• IP20 rating means it's protected from objects larger than 12mm in size

• Screw termination method is simple and doesn't need complex tools, saving time and effort

Applications


• Medical equipment

• Chemical laboratories

• Mechanical workshops

How durable is this RCBO?


This unit withstands 20,000 mechanical operating cycles and 5,000 electrical operating cycles, so you can depend on it for long-term performance.

What tripping characteristic does this device have?


The unit has a type B tripping characteristic, so it trips whenever there's a fault current that's 3 to 5 times its 20A current rating. This means it's highly sensitive and low-level current leakage can't sneak past it.

Schneider Electric Acti9 iC60H RCBOs Range


iC60H RCBO carries out complete protection of final circuits:

  • Protection against short-circuits and cable overloads

  • Protection of persons against electric shock by direct contact (10, 30 mA sensitivities)

  • Protection of persons against electric shock by indirect contact (100 mA sensitivity)

  • Protection of equipment against fires set by leakage currents (100 mA sensitivity)