ABB RCBO, 20A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range
- RS 제품 번호:
- 201-6957
- 제조사 부품 번호:
- 2CSR255180R1204 DS201 C20 A30
- 제조업체:
- ABB
Subtotal (1 unit)*
₩347,160.80
재고있음
- 4 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩347,160.80 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 201-6957
- 제조사 부품 번호:
- 2CSR255180R1204 DS201 C20 A30
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Current Rating | 20A | |
| Range | System Pro M Compact | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Series | DS201 | |
| Circuit Breaker Type | RCBO | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240V | |
| Mounting Style | DIN Rail Mount | |
| Special Features | Short Circuit Protection | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Reset Actuator Type | Toggle Switch | |
| Overall Length | 69mm | |
| Break Time | Instantaneous | |
| Overall Depth | 69mm | |
| Terminal Contact Type | Screw | |
| Overall Width | 35mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Current Rating 20A | ||
Range System Pro M Compact | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Series DS201 | ||
Circuit Breaker Type RCBO | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240V | ||
Mounting Style DIN Rail Mount | ||
Special Features Short Circuit Protection | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Reset Actuator Type Toggle Switch | ||
Overall Length 69mm | ||
Break Time Instantaneous | ||
Overall Depth 69mm | ||
Terminal Contact Type Screw | ||
Overall Width 35mm | ||
ABB DS201 Series RCBO, 20A Current Rating, 30mA Trip Sensitivity - 2CSR255180R1204 DS201 C20 A30
This RCBO is designed to offer effective protection for single-phase circuits against overloads and short circuits, making it a critical component for safety in electrical installations. The device is compact, with dimensions of 69mm x 35mm, and is intended for DIN rail mounting, providing a clean, organised solution for electrical distribution boards. Its robust features ensure reliable performance within a rated AC voltage of 240V.
Features & Benefits
• Provides short circuit protection to enhance safety
• Designed with 30 mA trip sensitivity for effective fault detection
• Features Type C tripping characteristics suited for inductive loads
• Installs easily on DIN rail for straightforward integration
• Boasts a breaking capacity of 10 kA for reliable fault interruption
• Equipped with a toggle switch for simple manual reset
• Designed with 30 mA trip sensitivity for effective fault detection
• Features Type C tripping characteristics suited for inductive loads
• Installs easily on DIN rail for straightforward integration
• Boasts a breaking capacity of 10 kA for reliable fault interruption
• Equipped with a toggle switch for simple manual reset
Applications
• Used for protecting individual circuits in residential installations
• Suitable for commercial requiring circuit overload protection
• Ideal for use in areas where direct contact safety is essential
• Employed in electrical panels to safeguard sensitive equipment
• Utilised in environments subject to earth fault conditions
• Suitable for commercial requiring circuit overload protection
• Ideal for use in areas where direct contact safety is essential
• Employed in electrical panels to safeguard sensitive equipment
• Utilised in environments subject to earth fault conditions
What is the significance of the 30 mA trip sensitivity in this device?
The 30 mA trip sensitivity is crucial as it helps to detect earth faults promptly, ensuring user safety by disconnecting the circuit before a potentially dangerous situation develops.
How does the breaking capacity of 10 kA benefit installations?
A breaking capacity of 10 kA means the device can handle high fault currents without sustaining damage, ensuring consistent operation during fault conditions while protecting downstream equipment.
What types of loads are suitable for a Type C tripping characteristic?
Type C tripping characteristics are suitable for circuits with inductive loads, such as motors and transformers, as they prevent nuisance tripping while offering reliable protection against overloads.
Can this device be used in harsh environmental conditions?
It is designed to operate effectively in environments with temperatures ranging from -25°C to +55°C, allowing it to function reliably across a variety of conditions.
What is the practical advantage of using DIN rail mounting for this product?
DIN rail mounting provides a secure and efficient installation method, allowing for easy assembly and disassembly in electrical cabinets, thus saving valuable time during maintenance or upgrades.
관련된 링크들
- ABB RCBO, 20A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
- ABB RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
- ABB RCBO, 8A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
- ABB RCBO, 10A Current Rating, 2P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
- ABB RCBO, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type C
- ABB RCBO, 20A Current Rating, 3P Poles, 30mA Trip Sensitivity, System Pro M Compact Range
- ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type B, System Pro M Compact Range
- ABB RCBO, 6A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, System Pro M Compact Range