Better World

Siemens Residual Current Circuit Breaker with Overload Protection, 13 A Current Rating, 2-Pole, 30 mA Trip Sensitivity,

Subtotal (1 unit)*

₩149,685.60

Add to Basket
수량 선택 또는 입력
재고있음
  • 61 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩149,685.60

* 참고 가격: 실제 구매가격과 다를 수 있습니다

Better World

Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.

RS 제품 번호:
187-3288
Distrelec 제품 번호:
301-49-285
제조사 부품 번호:
5SV1316-7KK13
제조업체:
Siemens
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Siemens

Product Type

Residual Current Circuit Breaker with Overload Protection

Current Rating

13 A

Series

5SV1316

Range

SENTRON

Number of Poles

2

Trip Sensitivity

30mA

Tripping Characteristics

Type C

Mount Type

DIN Rail

Rated AC Voltage

195 V ac

Terminal Type

Screw

Earth Leakage Protection Type

Type A

Width

18 mm

Height

90mm

Depth

77mm

Better World Product

Yes

Better World Claim

Concentrated or Compact Solution, Extended Product Life, Low Carbon Manufacture

Standards/Approvals

No

Breaking Capacity

6kA

COO (Country of Origin):
RO

Siemens 5SV1316 Series Residual Current Circuit Breaker with Overload Protection, 13A Current, 30mA Trip Sensitivity - 5SV1316-7KK13


This residual current circuit-breaker with overload protection provides combined earth-fault detection and overcurrent interruption for single-phase installations. Designed for DIN-rail fitting in distribution boards, it protects circuits by disconnecting on residual currents and instantaneous overloads while supporting AC supply systems at 230V and 50 Hz.

Features & Benefits


• Type A detection with 30 mA sensitivity for AC and pulsating faults
• 6 kA breaking capacity to limit fault energy and damage
• Type C instantaneous tripping for moderate inrush current tolerance
• Two-pole design enabling simultaneous live and NEUTRAL switching
• Screw terminals accepting up to 16mm² for robust conductor connections
• Compact width of 18mm conserving panel space

Applications


• Suitable for residential distribution boards requiring earth-leakage protection
• Ideal for small commercial installations with single-phase circuits
• Used for protecting lighting and socket circuits with moderate inrush currents
• Can be used for retrofit projects where DIN-rail mounting is required

What is the expected mechanical service life under normal switching?


The device is rated for approximately 10,000 switching cycles in typical mechanical operation.

How does ambient temperature affect rated current-carrying capability?


The rated 13A current is derated progressively with temperature, for example to about 12.35A at 40 °C and to about 10.01A at 70 °C.

What installation orientations and clearances are supported?


It may be mounted in any position on a standard DIN rail and offers IP20 protection when installed with conductors connected inside a distribution enclosure.

Which surge and switching performance figures are relevant for coordination?


Surge resistance is about 1 kA for an 8/20 μs waveform and switching capacities include 6 kA per EN 60898 and 15 kA per IEC 60947-2.

What conductor preparations and tightening parameters are required?


Stranded conductors up to 16mm² and finely stranded with ferrules up to 10mm² are acceptable and Terminal screws should be tightened to between 1.2 and 2 N·m.