Schneider Electric RCBO, 32A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- RS 제품 번호:
- 654-836
- 제조사 부품 번호:
- A9D19232
- 제조업체:
- Schneider Electric
Subtotal (1 unit)*
₩780,955.50
재고있음
- 7 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩780,955.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 654-836
- 제조사 부품 번호:
- A9D19232
- 제조업체:
- Schneider Electric
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Schneider Electric | |
| Product Type | RCBO | |
| Current Rating | 32A | |
| Number of Poles | 2 | |
| Series | iC60 | |
| Range | Acti9 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Terminal Type | Screw Clamp | |
| Height | 110mm | |
| Width | 18mm | |
| Depth | 72mm | |
| Breaking Capacity | 10000A | |
| Standards/Approvals | BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | |
| Application | Distribution | |
| 모두 선택 | ||
|---|---|---|
브랜드 Schneider Electric | ||
Product Type RCBO | ||
Current Rating 32A | ||
Number of Poles 2 | ||
Series iC60 | ||
Range Acti9 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Terminal Type Screw Clamp | ||
Height 110mm | ||
Width 18mm | ||
Depth 72mm | ||
Breaking Capacity 10000A | ||
Standards/Approvals BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | ||
Application Distribution | ||
- COO (Country of Origin):
- TH
The Schneider Electric Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 2P circuit breaker with 1 protected pole, 32A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life.
Neutral position is left
Number of protected poles is 1
Device location in system is outgoer
Network frequency is 50 Hz
관련된 링크들
- Schneider Electric RCBO, 20A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- Schneider Electric Residential RCBO, 4A Current Rating, 1-Pole, 30 mA Trip Sensitivity, B Curve, Acti9 Range, Acti9 iDPN
- Schneider Electric RCBO, 16A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type B, Acti9 Range, A9d Range
- Hager RCBO, 10A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type A, Hager Range, ADX Range
- Hager RCBO, 16A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type A, Hager Range, ADX Range
- Hager RCBO, 25A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type A, Hager Range, ADX Range
- Schneider Electric Contactor, 25A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Acti9 Arc Range
- Siemens RCBO, 6A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type B, SENTRON Range, 5SU Range