Hager Residual Current Circuit Breaker with Overload Protection, 32 A Current Rating, 4-Pole, 30 mA Trip Sensitivity,
- RS 제품 번호:
- 602-208
- 제조사 부품 번호:
- ADM482C
- 제조업체:
- Hager
Subtotal (1 unit)*
₩1,128,112.80
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량 | 한팩당 |
|---|---|
| 1 + | ₩1,128,112.80 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 602-208
- 제조사 부품 번호:
- ADM482C
- 제조업체:
- Hager
사양
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Hager | |
| Current Rating | 32 A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Number of Poles | 4 | |
| Series | ADM | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 400 V ac | |
| Terminal Type | Screw | |
| Earth Leakage Protection Type | Type A | |
| Height | 84mm | |
| Depth | 70mm | |
| Width | 71 mm | |
| Breaking Capacity | 6kA | |
| Application | Protection | |
| Standards/Approvals | IEC 60898-1 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Hager | ||
Current Rating 32 A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Number of Poles 4 | ||
Series ADM | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 400 V ac | ||
Terminal Type Screw | ||
Earth Leakage Protection Type Type A | ||
Height 84mm | ||
Depth 70mm | ||
Width 71 mm | ||
Breaking Capacity 6kA | ||
Application Protection | ||
Standards/Approvals IEC 60898-1 | ||
- COO (Country of Origin):
- PL
The Hager Residual Current Circuit Breaker provides reliable protection against overcurrents and earth leakage. It is designed to detect alternating fault currents, ensuring the safety of both people and property. This device also helps maintain compliance with current electrical standards. It operates effectively within a wide serving temperature range.
Screw terminal connections
RoHS compliant
관련된 링크들
- Hager Residual Current Circuit Breaker with Overload Protection, 10 A Current Rating, 4-Pole, 30 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 25 A Current Rating, 4-Pole, 30 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 20 A Current Rating, 4-Pole, 30 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 40 A Current Rating, 4-Pole, 30 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 16 A Current Rating, 4-Pole, 30 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 32 A Current Rating, 4-Pole, 30 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 16 A Current Rating, 3-Pole, 300 mA Trip Sensitivity,
- Hager Residual Current Circuit Breaker with Overload Protection, 20 A Current Rating, 3-Pole, 300 mA Trip Sensitivity,