Fluke Flexible Loop Current Probe, 45 mm Tip, 600 V, 7.5 mm Socket, 2500A

Subtotal (1 unit)*

₩418,074.40

Add to Basket
수량 선택 또는 입력
재고있음
  • 1 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩418,074.40

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
705-1954
Distrelec 제품 번호:
176-43-496
제조사 부품 번호:
Fluke i2500-18
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Product Type

Current Probe

Current

2500A

Probe Tip Type

Flexible Loop

Tip Size

45 mm

Probe Socket Diameter

7.5mm

Standards/Approvals

CAT IV 600 V, CAT III 1000 V

Length

6ft

COO (Country of Origin):
CN

Fluke Current Probe, 2500A Rated Current, 600V Rated Voltage - Fluke i2500-18


This flexible current probe is designed to extend AC current measurement capabilities for technicians and engineers working with high-current systems. It connects directly to compatible clamp meters, allowing measurements up to 2500 A AC while keeping the meter display separate from the sensing point. The 1.8m cable and large, thin loop form allow access to crowded wiring and awkward conductors, making it suitable for industrial and field environments where conductor routing and meter visibility are challenges.

Features & Benefits


• 2500 A AC range delivers high-current measurement capability
• 1500 Hz frequency response supports a wide signal spectrum
• 40 dB external magnetic field rejection reduces interference effects
• 7.5mm Coil socket enables use in confined spaces
• 45mm flexible loop permits measurement of larger conductors
• CAT IV 600V and CAT III 1000V rating supports mains-level work

Applications


• Suitable for motor start-up in automation systems
• Ideal for load studies on distribution panels
• Used for inverter and drive current analysis in electronics
• Can be used for commissioning in electrical installations
• Suitable for predictive maintenance in mechanical plant

What cable length separates the sensor from the meter for safer viewing?


The probe includes a 1.8m cable to allow separation between the loop and the meter display.

How does the probe handle inrush current measurements?


It is specified to measure inrush when used with a compatible meter, with accuracy statements incorporating both probe and meter contributions.

What positional sensitivity should I expect when the conductor is off-centre?


Position sensitivity varies with offset

at 35.6mm from optimum accuracy changes by ±0.5%, at 50.8mm by ±1.0%, and at 63.5mm by ±2.0%.

Which electrical safety standards apply to this device?


The device conforms to IEC 61010-2-032 with CAT III 1000V and CAT IV 600V safety classifications.

How resistant is the probe to nearby magnetic fields during measurement?


With the cable kept more than 10 cm from the probe coupling, external magnetic field rejection is rated at 40 dB.