Honeywell Technologies SSCDANN100PG5A5 Piezoresistive Pressure SensorThrough Hole 8 DIP

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

대량 구매 할인 기용 가능
View bulk pricing options

Subtotal (1 Box of 50 units)*

₩3,875,300.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 12월 02일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.

수량
한팩당
Per Box*
50 - 200₩77,506.00₩3,875,320.00
250 +₩75,956.00₩3,797,800.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
226-9721
제조사 부품 번호:
SSCDANN100PG5A5
제조업체:
Honeywell
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell

Maximum Overload Pressure

1723kPa

Sensor Type

Piezoresistive Pressure Sensor

Product Type

Piezoresistive Pressure Sensor

Mount Type

Through Hole

Package Type

DIP

Pin Count

8

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

689 kPa

Maximum Supply Voltage

5V

Accuracy

±0.25 %

Port Type

Single Axial Barbed

Maximum Operating Temperature

85°C

Length

10mm

Height

13.75mm

Series

SSC

Standards/Approvals

No

Minimum Operating Pressure

0psi

Automotive Standard

No

Minimum Operating Temperature

-40°C

Honeywell SSC Series Piezoresistive Pressure Sensor, 0 to 689kPa Maximum Operating Pressure, ±0.25% Accuracy - SSCDANN100PG5A5


This piezoresistive pressure sensor converts applied fluid pressure into an electrical signal for measurement and control in low-pressure systems. It operates from a low voltage and is supplied in a through-hole package with a single axial barbed port suitable for tubing connections. The device is specified for general industrial use across a wide ambient range and provides a Compact footprint for board-mounted assemblies.

Features and Benefits:


• 3.3V to 5V operation enables flexible supply configurations
• ±0.25% accuracy pressure transducer delivers precise readings
• 0 psi minimum pressure supports vacuum-to-pressure monitoring
• 1723kPa overload rating protects against transient spikes
• Operating range -40 to 85°C maintains performance in extremes

Applications


• Suitable for laboratory low-pressure measurement setups
• Ideal for pneumatic control and monitoring systems
• Used with tubing for fluid pressure sampling tasks
• Can be used for industrial transmitter prototypes needing accuracy
• Compatible with through-hole assembly for retrofit installations

What electrical supply limits apply?


It operates from 3.3V minimum up to 5V maximum.

How many electrical connections are required?


The device uses an 8-pin DIP package for signal and power terminations.

What environmental temperatures can it withstand?


It is rated to function between -40°C minimum and 85°C maximum.

What mechanical port and mounting formats are provided?


It employs a single axial barbed port and through-hole mounting for secure tubing and PCB attachment.