Honeywell Technologies ABPDJNN001PDAA3 Piezoresistive Pressure SensorBoard 6 DIP
- RS 제품 번호:
- 226-9604
- 제조사 부품 번호:
- ABPDJNN001PDAA3
- 제조업체:
- Honeywell Technologies
본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.
현재 비가용
RS는 이 제품을 더 이상 판매하지 않습니다.
- RS 제품 번호:
- 226-9604
- 제조사 부품 번호:
- ABPDJNN001PDAA3
- 제조업체:
- Honeywell Technologies
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell Technologies | |
| Sensor Type | Gauge Pressure Sensor | |
| Product Type | Piezoresistive Pressure Sensor | |
| Maximum Overload Pressure | 69kPa | |
| Mount Type | Board | |
| Package Type | DIP | |
| Pin Count | 6 | |
| Minimum Supply Voltage | -0.3V | |
| Maximum Operating Pressure | 6.89 kPa | |
| Maximum Supply Voltage | 5V | |
| Accuracy | ±0.25 % | |
| Port Type | Single Radial Barbless | |
| Maximum Operating Temperature | 85°C | |
| Width | 6.3mm | |
| Height | 3.63mm | |
| Length | 7.3mm | |
| Standards/Approvals | BPA Free, LFGB, NSF-169 | |
| Series | ABP | |
| Minimum Operating Pressure | 0psi | |
| Automotive Standard | ISO 9001 | |
| Minimum Operating Temperature | -40°C | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell Technologies | ||
Sensor Type Gauge Pressure Sensor | ||
Product Type Piezoresistive Pressure Sensor | ||
Maximum Overload Pressure 69kPa | ||
Mount Type Board | ||
Package Type DIP | ||
Pin Count 6 | ||
Minimum Supply Voltage -0.3V | ||
Maximum Operating Pressure 6.89 kPa | ||
Maximum Supply Voltage 5V | ||
Accuracy ±0.25 % | ||
Port Type Single Radial Barbless | ||
Maximum Operating Temperature 85°C | ||
Width 6.3mm | ||
Height 3.63mm | ||
Length 7.3mm | ||
Standards/Approvals BPA Free, LFGB, NSF-169 | ||
Series ABP | ||
Minimum Operating Pressure 0psi | ||
Automotive Standard ISO 9001 | ||
Minimum Operating Temperature -40°C | ||
Honeywell ABP Series Piezoresistive Pressure Sensor, 6.89 kPa Maximum Operating Pressure, ±0.25 % Accuracy - ABPDJNN001PDAA3
This piezoresistive pressure sensor converts pressure into a ratiometric electronic signal for board-mounted measurement in gas or liquid environments. It is a compensated, calibrated device offering analogue or digital outputs and is suitable for reading gauge and differential pressures across a defined full-scale range while operating from a single low-voltage supply.
Features and Benefits:
• ±0.25%FSS accuracy reduces measurement uncertainty
• Total error band ±1.5%FSS for worst-case error assessment
• Operates from 3.3V or 5V supply for design flexibility
• Calibrated output update rates up to 2kHz for digital
• Sleep mode draws microamp current for battery applications
• Temperature operation −40°C to 85°C for broad environments
• Total error band ±1.5%FSS for worst-case error assessment
• Operates from 3.3V or 5V supply for design flexibility
• Calibrated output update rates up to 2kHz for digital
• Sleep mode draws microamp current for battery applications
• Temperature operation −40°C to 85°C for broad environments
Applications
• Used for CPAP and ventilator pressure monitoring
• Suitable for blood analysis and blood-pressure instruments
• Ideal for pneumatic control and valve position sensing
• Used with coffee machines and washing-machine control
• Suitable for HVAC transmitters and process gas monitoring
• Suitable for blood analysis and blood-pressure instruments
• Ideal for pneumatic control and valve position sensing
• Used with coffee machines and washing-machine control
• Suitable for HVAC transmitters and process gas monitoring
What media can the sensor tolerate internally?
Dry-gas variants accept non-corrosive, non-ionic gases while liquid-media variants include a silicone-based gel protecting electronics to permit exposure to non-corrosive liquids and condensation.
How is long-term output stability specified?
Long-term stability is specified as ±0.25%FSS after 1,000 hours at 25°C, indicating minimal drift over time.
What output options are available for interfacing?
Outputs include ratiometric analogue and 12-bit digital compatible with I2C or SPI bus protocols.
What package and mounting styles are offered?
It is supplied in board-mount packages including DIP, SMT and leadless SMT for direct PCB assembly.
Which certifications cover food-contact safety for wet options?
Sensor materials used with the liquid-media option have been certified to NSF-169, BPA-free, and LFGB standards.
관련된 링크들
- Honeywell Technologies Piezoresistive Pressure SensorThrough Hole 6 DIP
- Honeywell Technologies SSCDRRN001PDAA5 Piezoresistive Pressure SensorThrough Hole 8 DIP
- Honeywell Technologies ABP2DRRT001PDAA3XX Piezoresistive Pressure SensorThrough Hole 6 DIP
- Honeywell Technologies Piezoresistive Pressure SensorThrough Hole 8 DIP
- Honeywell Technologies SSCDRRV015PDAA5 Piezoresistive Pressure SensorThrough Hole 8 DIP
- Honeywell Technologies HSCDRRV001PDAA5 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell Technologies ABPDRRV001PDAA5 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell Technologies HSCDANV001BAAA5 Piezoresistive Pressure SensorThrough Hole 8 DIP