Honeywell Technologies SSCDRRV100MGAA5 Gauge Pressure SensorThrough Hole 8 DIP

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

대량 구매 할인 기용 가능
View bulk pricing options

Subtotal (1 unit)*

₩101,420.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2027년 1월 11일 부터 100 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.

수량
한팩당
1 - 12₩101,420.00
13 - 24₩99,180.00
25 +₩97,060.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
214-1518
제조사 부품 번호:
SSCDRRV100MGAA5
제조업체:
Honeywell Technologies
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell Technologies

Product Type

Gauge Pressure Sensor

Maximum Overload Pressure

850mbar

Sensor Type

Gauge Pressure Sensor

Mount Type

Through Hole

Package Type

DIP

Pin Count

8

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

100 mbar

Accuracy

±0.25 %

Maximum Supply Voltage

5V

Port Type

Dual Radial Barbed

Maximum Operating Temperature

85°C

Length

10mm

Height

13.75mm

Series

SSC

Standards/Approvals

No

Minimum Operating Pressure

0mbar

Minimum Operating Temperature

-40°C

Automotive Standard

No

Honeywell SSC Series Gauge Pressure Sensor, 0 to 100mbar Measurement Range, ±0.25% Accuracy - SSCDRRV100MGAA5


This gauge pressure sensor measures low positive pressures and converts them into an electrical output suitable for instrumentation and control systems. It operates from a low-voltage supply and is intended for through-hole mounting where a compact, board-mounted transducer with barbed ports is required. The sensor functions across a wide ambient temperature span, allowing use in environments with significant thermal variation.

Features and Benefits:


• Operates from 3.3V to 5V supply for flexible integration
• Measures 0 to 100mbar for precise low-pressure detection
• ±0.25% accuracy supports high-precision measurement tasks
• Dual radial barbed ports enable simple tubing connections
• Eight-pin through-hole package offers firm PCB attachment

Applications


• Suitable for laboratory low-pressure calibration setups
• Ideal for medical device air-flow monitoring subsystems
• Used with pneumatic control loops in instrumentation panels
• Can be used for environmental chamber pressure monitoring
• Suitable for HVAC differential pressure sensing modules

What temperature range can it withstand?


It is specified to operate between -40°C and 85°C.

What mechanical connection does it provide for tubing?


It has two radial barbed ports designed for flexible tubing connections.

How is it mounted to a circuit board?


The unit uses an eight-pin package with through-hole pins for soldered mounting.

What pressure overload can it tolerate without damage?


It can withstand up to 850mbar of overload pressure.