Fluke 1587 Multimeter Kit Multimeter Kit

Subtotal (1 unit)*

₩2,426,516.00

Add to Basket
수량 선택 또는 입력
제한된 재고
  • 2 개 단위 배송 준비 완료
  • 추가로 2026년 4월 16일 부터 2 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩2,426,516.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
905-5923
Distrelec 제품 번호:
300-47-588
제조사 부품 번호:
FLUKE-1587/MDT FC
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Product Type

Multimeter Kit

Model Number

1587

Application

Electrical

Kit Contents

AC Current Clamp, Phase Rotation Indicator, Multimeter

Kit Type

Multimeter Kit

Standards/Approvals

TUV, UL, CE, CSA

제외

COO (Country of Origin):
CN

Fluke Multimeter Kit, Advanced Motor and Drive Troubleshooting Kit Type, Electrical Application - FLUKE-1587/MDT FC


This multimeter kit combines a true-rms digital multimeter with insulation test capability and targeted accessories for Advanced motor and drive troubleshooting in industrial settings. It is built for field service and preventative maintenance, providing insulation resistance measurements across multiple test voltages alongside standard multimeter functions and connectivity for data capture and analysis.

Features & Benefits


• Insulation range 0.01MΩ–2GΩ enabling high-resistance diagnosis
• Test voltages 50V–1000V for diverse insulation tasks
• Live-circuit detection inhibits tests above 30V for safety
• VFD low-pass filter improves motor drive voltage readings
• AC/DC current and voltage measurements with true-rms response
• Wireless data transfer for timed PI/DAR trend analysis

Applications


• Suitable for commissioning and fault-finding on VFD systems
• Ideal for preventative insulation surveys on motors and cables
• Used for on-site motor drive diagnostics with AC current clamp
• Can be used for electrical maintenance in automation plants
• Used with phase rotation indicator for rotating machinery checks

What battery type and expected operational endurance does it use


It runs on four AA batteries and supports about 1000 hours of meter use with standard alkaline cells.

How does the tool manage capacitive discharge after testing


The instrument auto-discharges capacitive voltage in under 0.5 s for C ≤ 1 μF to remove stored charge before handling.

Which environmental conditions affect operation limits


It operates between -20°C and 55°C and tolerates up to 95% non‑condensing humidity at 10°C–30°C with reduced limits at higher temperatures.

What protection is provided for current input overloads


The mA input is fuse-protected with a 0.44 A, 1000V fuse and allows 600 mA overload for short periods.

How are frequency and capacitance measured for diagnostics


Frequency measurement extends to 99.99 kHz with high resolution and capacitance ranges up to 9999 μF for motor and component testing.