Fluke 1664 UK FTT Electrical Installation Tester Bundle 1000 V Earth Resistance Measurement

Subtotal (1 unit)*

₩5,080,624.80

Add to Basket
수량 선택 또는 입력
재고있음
  • 2 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩5,080,624.80

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
250-6935
제조사 부품 번호:
1664 UK FTT
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Product Type

Electrical Installation Tester Bundle

Loop Impedance Test Type

Phase to Neutral, Phase to Earth

Automatic RCD Test

Yes

RCD Ramp Test

Yes

Model Number

1664 UK FTT

Non-Tripping

Yes

Insulation Test Voltage

1000 V

Maximum Voltage Measurement

500V

Earth Resistance Measurement

Yes

Downloadable Data

Yes

RCD Test Type

AC

Weight

1.3kg

Length

1000000.00mm

Height

25mm

Width

25 cm

Standards/Approvals

UL61010, ANSI/ISA, CAN/CSA c22.2 No. 1010 2nd edition, EN610101 Ed 2.0

Test Standards

EN61557-10 Second Edition, EN61557-1 to EN61557-7 Second Edition

IP Rating

IP40

Power Source

Battery

Battery Type

AA

Safety Category Level

CAT IV 300 V, Philips

Safety Category Voltage

500V

COO (Country of Origin):
GB

Fluke Electrical Installation Tester Bundle, 1000V Insulation Test Voltage, 500V Maximum Voltage Measurement - 1664 UK FTT


This electrical installation tester bundle is a handheld multifunction installation tester designed for comprehensive verification of fixed electrical installations and EV charging protective devices. It runs automated test sequences, protects connected appliances during insulation checks, and transmits measurement results wirelessly to smartphones while storing data for later analysis.

Features & Benefits


• Auto Test runs seven sequential installation tests to save time
• Insulation pre-test prevents damage by detecting connected appliances
• RCD ramp test electrical tester performs VAR mode for smooth DC
• Earth resistance measurement tester offers 25V output at 128Hz
• non-tripping continuity tester 1mA uses low-current measurement for windings
• loop impedance phase to earth tester measures L-PE and L-N in parallel

Applications


• Suitable for commissioning and verification of installations to local regulations
• Ideal for testing EV charging stations with RDC-DD and RCD type A-EV monitors
• Used for maintenance checks where shared, cloud-stored results are required
• Can be used for ring final circuit testing without changing connections
• Used with high-current loop mode for Rapid impedance surveys

How are results transferred and archived in the field?


Measurement data can be sent to a mobile device and saved to Cloud storage via the manufacturer’s wireless system and associated software for report generation.

Which RCD types and test currents are supported for tripping and ramp tests?


The unit exercises AC, A and B-compatible VAR modes, including 6mA/60mA/200mA profiles for EV/DC monitor testing and stepped/linear rising tests across specified percentage ranges of rated current.

What continuity and insulation test ranges does it provide?


Continuity is autoranging to 2000Ω with resolution down to 0.01Ω and insulation tests selectable up to 1000V with multiple resistance ranges suited to various test voltages.

How does the instrument handle loop and fault current assessment?


It measures loop and line impedance with hi-current and standard modes, computes prospective earth fault current or prospective short-circuit current from measured voltage and impedance, and stores Peak loop values.