Dold BA9010 Soft Starter 400V, 5.5 kW, 1 Phase, IP30
- RS 제품 번호:
- 240-9140
- 제조사 부품 번호:
- BA9010 3AC230/400V 1.5/3kW
- 제조업체:
- Dold
대량 구매 할인 기용 가능
Subtotal (1 unit)*
₩427,908.00
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량 | 한팩당 |
|---|---|
| 1 - 4 | ₩427,908.00 |
| 5 + | ₩352,170.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 240-9140
- 제조사 부품 번호:
- BA9010 3AC230/400V 1.5/3kW
- 제조업체:
- Dold
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Dold | |
| Power Rating | 5.5kW | |
| Product Type | Soft Starter | |
| Number of Phases | 1 | |
| IP Rating | IP30 | |
| Mount Type | DIN Rail | |
| Maximum Supply Voltage | 400V | |
| Overall Length | 121mm | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | CE | |
| Overall Width | 45mm | |
| Overall Depth | 74mm | |
| Series | BA9010 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Dold | ||
Power Rating 5.5kW | ||
Product Type Soft Starter | ||
Number of Phases 1 | ||
IP Rating IP30 | ||
Mount Type DIN Rail | ||
Maximum Supply Voltage 400V | ||
Overall Length 121mm | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals CE | ||
Overall Width 45mm | ||
Overall Depth 74mm | ||
Series BA9010 | ||
- COO (Country of Origin):
- DE

Soft starter, BA9010
One of the three motor phases is influenced in the BA9010 by phase control in such a way that the current in this phase rises steadily. The motor torque behaves in exactly the same way during start-up. This guarantees that the drive can start up without jerking. It is thus impossible for drive elements to be damaged, because the abrupt starting torque caused by direct starting is not generated. This property enables a cost-efficient design for the drive elements.
A marked reduction of starting noise is also perceived. Slippage or tipping over of items being conveyed on belts is avoided.
After starting, the power electronics are bridged via an internal relay contact to minimise losses in the device.
Applications
Machines with gear, belt and chain drives
Conveyor belts, fans, pumps, compressors
Packaging machines, door operating mechanisms
Inrush current limitation for single-phase transformers
Features
Increases the service life of asynchronous motors and mechanical drive components
For motor ratings up to 3 kW
Single-phase motor control
Easy installation even in existing systems
No need for a neutral conductor
Starting time and starting torque can be adjusted separately.
Can be combined with motor brake units.
Suitable for snapping onto a 35 mm standard top-hat rail
An f/V converter is frequently not needed for simple applications
Power semiconductor bridged after successful start-up
LED displays
Overall width 45 mm
Warning
If devices are used in 230 V three-phase networks, the next higher power stage must be used for a given motor power, because the motor current determines the overall size of the device.
The starting current in the network cannot be lowered with these devices. In order to achieve this simultaneously with torque reduction, the BA9026 must be used, for example.
The BA9010 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.
관련된 링크들
- Dold BA9026 Soft Starter 460V ac, 3 kW, 3 Phase, IP20, IP40
- Dold Soft Starter 230V, 1.5 kW, 1 Phase, IP20, IP40
- Dold UH9018 Soft Starter 400V ac, 1.5 kW, 3 Phase, IP20
- Dold Soft Start 400V ac, 5.5 kW, 2 Phase, IP30
- Dold UG9256 Soft Starter 480V ac, 4 kW, 3 Phase, IP20, IP40
- Dold PF 9015 Motor Starter, Soft Start, 200V, 7.5 kW, 3 Phase, IP40, IP20
- Dold BL9025 Soft Starter 480V ac, 15 kW, 3 Phase, IP20, IP40
- Dold PF 9015 Motor Starter, Soft Start, 480V, 7.5 kW, 3 Phase, IP40, IP20