Eaton S811+V72P3S Soft Starter 600V ac, 750 HP, 3 Phase, IP20
- RS 제품 번호:
- 120-344
- 제조사 부품 번호:
- 169006 S811+V72P3S
- 제조업체:
- Eaton
Subtotal (1 unit)*
₩21,240,640.00
일시적 품절
- 2026년 12월 07일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩21,240,640.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 120-344
- 제조사 부품 번호:
- 169006 S811+V72P3S
- 제조업체:
- Eaton
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Eaton | |
| Power Rating | 750HP | |
| Product Type | Soft Starter | |
| Number of Phases | 3 | |
| IP Rating | IP20 | |
| Maximum Supply Voltage | 600V ac | |
| Overall Length | 187.8mm | |
| Maximum Operating Temperature | 50°C | |
| Overall Width | 280.6mm | |
| Standards/Approvals | CSA-C22.2 No. 14-05, CSA Class No.: 3211-07, UL File No.: E54120, UL, UL Category Control No.: MITW2, IEC/EN 60947-3, CSA-C22.2 No. 94, CSA, UL 508, CSA File No.: 012528, CE | |
| Overall Depth | 187.8mm | |
| Series | S811+V72P3S | |
| 모두 선택 | ||
|---|---|---|
브랜드 Eaton | ||
Power Rating 750HP | ||
Product Type Soft Starter | ||
Number of Phases 3 | ||
IP Rating IP20 | ||
Maximum Supply Voltage 600V ac | ||
Overall Length 187.8mm | ||
Maximum Operating Temperature 50°C | ||
Overall Width 280.6mm | ||
Standards/Approvals CSA-C22.2 No. 14-05, CSA Class No.: 3211-07, UL File No.: E54120, UL, UL Category Control No.: MITW2, IEC/EN 60947-3, CSA-C22.2 No. 94, CSA, UL 508, CSA File No.: 012528, CE | ||
Overall Depth 187.8mm | ||
Series S811+V72P3S | ||
- COO (Country of Origin):
- DO
Eaton Soft Starter, 750 hp Power Rating, 720A Current Rating - 169006 S811+V72P3S
This soft starter is designed to efficiently manage the operation of three-phase motors with a power rating of 750 hp and a voltage capability of up to 600 V AC. Measuring 187.8mm in length, 280.6mm in width, and 420.8mm in height, the device weighs 41.4 kg. It features Advanced control units along with a pump algorithm, ensuring smooth motor start-ups and enhanced operational safety.
Features & Benefits
• Integrated motor overload protection safeguards against potential damage
• Internal bypass contacts reduce energy losses during operation
• Soft start function minimises mechanical stress during motor activation
• Fault memory storage records up to 10 faults for diagnostic purposes
• Underload monitoring helps identify performance issues proactively
• Modbus RTU Interface enables easy integration into control systems
• Internal bypass contacts reduce energy losses during operation
• Soft start function minimises mechanical stress during motor activation
• Fault memory storage records up to 10 faults for diagnostic purposes
• Underload monitoring helps identify performance issues proactively
• Modbus RTU Interface enables easy integration into control systems
Applications
• Used for soft starting of three-phase asynchronous motors
• Applicable in industrial machinery requiring high current control
• Ideal for pumps needing precise motor control and programming
• Effective in automation systems for reliable motor management
• Suitable for environments with harsh conditions due to IP20 rating
• Applicable in industrial machinery requiring high current control
• Ideal for pumps needing precise motor control and programming
• Effective in automation systems for reliable motor management
• Suitable for environments with harsh conditions due to IP20 rating
How does the internal bypass enhance energy efficiency?
The internal bypass contacts allow current to flow directly to the motor once the soft start process is complete, reducing power losses and improving energy efficiency during operation.
What voltage range can be effectively managed by this device?
It successfully operates within a voltage range of 200 to 600 V AC, making it versatile for various industrial applications.
How does the fault memory function assist in maintenance?
The fault memory can store up to 10 previous faults, enabling maintenance teams to analyse issues swiftly and implement corrective actions, ultimately increasing system reliability.
What type of control system compatibility does it offer?
This model features a Modbus RTU interface, facilitating seamless communication with diverse industrial control systems for streamlined operation.
What environmental conditions can it withstand?
It is designed to function effectively in ambient temperatures ranging from -30°C to 50°C, accommodating a variety of challenging environments.
관련된 링크들
- Eaton S811+V72V3S Soft Starter 690V, 750 HP, 3 Phase, IP20
- Eaton S811+U42P3S Soft Starter 600V ac, 750 HP, 3 Phase, IP20
- Eaton S811+V65V3S Soft Starter 690V, 750 HP, 3 Phase, IP20
- Eaton S811+V50P3S Soft Starter 600V ac, 500 HP, 3 Phase
- Eaton S811+V42P3S Soft Starter 600V ac, 450 HP, 3 Phase
- Eaton S811+V85P3S Soft Starter 600V ac, 850 HP, 3 Phase
- Eaton S811+V65P3S Soft Starter 600V ac, 600 HP, 3 Phase
- Eaton S811+U36P3S Soft Starter 600V ac, 600 HP, 3 Phase