Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 10A to 200A, 0 V ac, 0V ac
- RS 제품 번호:
- 111-3096
- 제조사 부품 번호:
- K8DT-AS3CD
- 제조업체:
- Omron
Subtotal (1 unit)*
₩339,202.50
일시적 품절
- 2026년 8월 05일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩339,202.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 111-3096
- 제조사 부품 번호:
- K8DT-AS3CD
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 1 | |
| Contact Configuration | SPDT | |
| Mount Type | DIN Rail | |
| Minimum Current Sensed | 10A | |
| Power Consumption | 1.8VA | |
| Maximum Current Sensed | 200A | |
| Current Sensitivity | Undercurrent, Overcurrent | |
| Terminal Type | Push-in | |
| IP Rating | IP20 | |
| Time Delay | 250 ms | |
| Supply AC Voltage | 0V ac | |
| Relay Contact Current | 10, 200mA | |
| Supply DC Voltage | 0 V ac | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Series | K8DT-AS | |
| Width | 17.5mm | |
| Standards/Approvals | RoHS, UL 60947-5-1, EN 60947-5-1 | |
| Length | 90mm | |
| Height | 90mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Monitoring Relay | ||
Electrical Phase 1 | ||
Contact Configuration SPDT | ||
Mount Type DIN Rail | ||
Minimum Current Sensed 10A | ||
Power Consumption 1.8VA | ||
Maximum Current Sensed 200A | ||
Current Sensitivity Undercurrent, Overcurrent | ||
Terminal Type Push-in | ||
IP Rating IP20 | ||
Time Delay 250 ms | ||
Supply AC Voltage 0V ac | ||
Relay Contact Current 10, 200mA | ||
Supply DC Voltage 0 V ac | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Series K8DT-AS | ||
Width 17.5mm | ||
Standards/Approvals RoHS, UL 60947-5-1, EN 60947-5-1 | ||
Length 90mm | ||
Height 90mm | ||
- COO (Country of Origin):
- CN
Omron K8DT-AS Series Monitoring Relay, 200A Maximum Current Sensed, 10A Minimum Current Sensed - K8DT-AS3CD
This monitoring relay provides single-phase current supervision for protection against both undercurrent and overcurrent conditions in industrial control systems. Designed for DIN-rail mounting, it offers a Compact control Interface and field-friendly terminals for integration into automation panels where current thresholds and short response times are required.
Features and Benefits:
• Detects currents from 10A to 200A for broad monitoring range
• Responds to faults with a 250 MS time delay for quick action
• SPDT contact provides versatile switching of control circuits
• Push-in terminals enable Rapid wiring and maintenance
• Operates across −20 °C to 60 °C for varied site environments
• Low power draw of 1.8 VA minimises supply loading
• Responds to faults with a 250 MS time delay for quick action
• SPDT contact provides versatile switching of control circuits
• Push-in terminals enable Rapid wiring and maintenance
• Operates across −20 °C to 60 °C for varied site environments
• Low power draw of 1.8 VA minimises supply loading
Applications
• Suitable for motor load supervision in industrial panels
• Ideal for detecting phase loss or reduced load conditions
• Used with control systems requiring fast trip signalling
• Can be used for process equipment current monitoring
• Suitable for retrofit into existing DIN-rail distribution boards
• Ideal for detecting phase loss or reduced load conditions
• Used with control systems requiring fast trip signalling
• Can be used for process equipment current monitoring
• Suitable for retrofit into existing DIN-rail distribution boards
What contact current can it switch for control signalling?
The relay contacts are specified to handle currents in the range 10 mA to 200 mA for interfacing with downstream control devices.
Which environmental protection does it offer for panel mounting?
The enclosure carries an IP20 rating suitable for protection within enclosed control cabinets but not for exposed outdoor locations.
How is the unit secured within a control enclosure?
It attaches to standard DIN rails and presents a slim profile to conserve rail space.
Are there approvals relevant to industrial electrical installations?
It meets recognised standards including RoHS and the specified EN and UL control-relay standards for use in compliant systems.
Note
K8DT-AS allow use in either overcurrent or undercurrent mode.
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
Standards
EN 60947-5-1, UL 60947-5-1, IP 20 Terminals
관련된 링크들
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 0.1A to 5A, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 2mA to 500mA, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 0V ac
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 0V ac 0 V ac
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 0.1A to 5A, 0V ac
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 10A to 200A, 0V ac
- Omron Monitoring Relay, 3 Phase, SPDT, Screw, DIN Rail
- Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, Screw, 10A to 200A, 24V ac