Crouzet Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 194 → 528 V, DIN Rail
- RS 제품 번호:
- 262-003
- 제조사 부품 번호:
- 84873026
- 제조업체:
- Crouzet
Subtotal (1 unit)*
₩339,246.00
재고있음
- 추가로 2025년 12월 05일 부터 8 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩339,246.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 262-003
- 제조사 부품 번호:
- 84873026
- 제조업체:
- Crouzet
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Crouzet | |
| Monitoring Application | Phase, Voltage | |
| Electrical Phase | 3 | |
| Voltage Sensing Range | 194 → 528 V | |
| Contact Configuration | DPDT | |
| Voltage Sensitivity | Overvoltage, Undervoltage | |
| Mounting Type | DIN Rail | |
| Phase Sensitivity | Phase Asymmetry, Phase Failure, Phase Sequence | |
| Time Delay | 0.1 → 10s | |
| Series | HWUA | |
| Width | 35mm | |
| Maximum Operating Temperature | +50°C | |
| Operating Temperature Range | +50°C | |
| Minimum Voltage Sensed | 194 V | |
| Minimum Operating Temperature | -20°C | |
| Length | 69mm | |
| Height | 92.6mm | |
| Maximum Voltage Sensed | 528V | |
| Dimensions | 69 x 35 x 92.6mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Crouzet | ||
Monitoring Application Phase, Voltage | ||
Electrical Phase 3 | ||
Voltage Sensing Range 194 → 528 V | ||
Contact Configuration DPDT | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Mounting Type DIN Rail | ||
Phase Sensitivity Phase Asymmetry, Phase Failure, Phase Sequence | ||
Time Delay 0.1 → 10s | ||
Series HWUA | ||
Width 35mm | ||
Maximum Operating Temperature +50°C | ||
Operating Temperature Range +50°C | ||
Minimum Voltage Sensed 194 V | ||
Minimum Operating Temperature -20°C | ||
Length 69mm | ||
Height 92.6mm | ||
Maximum Voltage Sensed 528V | ||
Dimensions 69 x 35 x 92.6mm | ||
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.
Control of 3 phase networks: phase sequence, phase failure, asymmetry, under and overvoltage with independent settings
Multi function / Multi-voltage product
True RMS measurement
LED status indication
Multi function / Multi-voltage product
True RMS measurement
LED status indication
관련된 링크들
- Crouzet Voltage Monitoring Relay, 3 Phase, DPDT, 194 → 528V ac, DIN Rail
- Crouzet Voltage Monitoring Relay, DPDT, 194 → 528V ac
- Schneider Electric Voltage Monitoring Relay, 3 Phase, DPDT, 194 → 528V ac, DIN Rail
- Crouzet Phase, Voltage Monitoring Relay, 3 Phase, SPDT, 183 → 528V ac, DIN Rail
- Crouzet Voltage Monitoring Relay, 3 Phase, SPDT, 183 → 528V ac, DIN Rail
- Crouzet Phase Monitoring Relay, 3 Phase, DPDT, DIN Rail
- Crouzet Voltage Monitoring Relay, 3 Phase, DPDT, 96 → 332V ac, DIN Rail
- Crouzet Current Monitoring Relay, 3 Phase, DPDT, DIN Rail