ABB, Tmax XT, Tmax XT Molded Case Circuit Breaker 3-Pole 52A, Breaking Capacity 65 kA, Fixed

Subtotal (1 unit)*

₩550,560.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 1 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩550,560.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
237-6225
제조사 부품 번호:
1SDA067051R1 XT2N 160 MA 52 FF
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Product Type

Molded Case Circuit Breaker

Range

Tmax XT

Series

Tmax XT

Number of Poles

3

Current Rating

52A

Breaking Capacity

65kA

Rated AC Voltage

690V ac

Mount Type

Fixed

Rated DC Voltage

500V dc

Terminal Type

Fixed

Depth

82.5mm

Height

130mm

Width

90mm

Standards/Approvals

IEC, RoHS, CE

Reset Actuator Type

Lever

Tripping Mechanism

Magnetic

COO (Country of Origin):
IT

ABB Tmax XT Series Molded Case Circuit Breaker, 52A Current Rating, 65kA Breaking Capacity - 1SDA067051R1 XT2N 160 MA 52 FF


This moulded case circuit breaker provides overcurrent protection for three-phase industrial installations, functioning as a fixed-terminal protective device with a manual reset lever. It is intended for use in electrical distribution and motor protection where Compact fixed mounting and magnetic tripping are required.

Features and Benefits:


• 65kA breaking capacity delivers high fault interruption performance • 52A rating enables defined protection for medium-current circuits • Magnetic trip operation offers Rapid short-circuit response • Fixed Terminal arrangement simplifies secure panel installation • Rated for 690V AC and 500V DC supports mixed-supply environments • Conforms to IEC, RoHS and CE standards for regulatory alignment

Applications


• Suitable for protecting industrial motor circuits requiring fast fault isolation • Ideal for distribution panels in manufacturing and automation centres • Used with DC and AC supplies in mixed-voltage installations • Can be used for switchgear retrofits needing a Compact fixed MCCB

How is the device reset after a trip?


A manual lever actuator is provided to return the breaker to service following a trip event.

What pole configuration does the unit use?


It uses a three-pole arrangement to interrupt all phases simultaneously for balanced system protection.

What mounting approach is required for installation?


The breaker is designed for fixed mounting and requires secure attachment to a panel or enclosure.

Which Terminal type is fitted and how does that affect connections?


Fixed terminals are used, requiring appropriate cable lugs and secure bolted connections during wiring.

관련된 링크들