ABB, Tmax XT, 1SDA06 Molded Case Circuit Breaker 4-Pole 125A, Breaking Capacity 4 kA, Fixed

Subtotal (1 unit)*

₩897,860.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 5 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩897,860.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
236-7280
제조사 부품 번호:
1SDA067409R1 XT1C 160 TMD 125A FF
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Product Type

Molded Case Circuit Breaker

Range

Tmax XT

Series

1SDA06

Number of Poles

4

Current Rating

125A

Breaking Capacity

4kA

Mount Type

Fixed

Rated AC Voltage

690V ac

Rated DC Voltage

500V dc

Terminal Type

Screw

Height

130mm

Standards/Approvals

IEC

Width

101.6mm

Depth

70mm

Break Time

Instantaneous

Tripping Mechanism

Thermomagnetic

COO (Country of Origin):
IT

ABB 1SDA06 Series Molded Case Circuit Breaker, 125A Current Rating, 690V AC Rated AC Voltage - 1SDA067409R1 XT1C 160 TMD 125A FF


This moulded case circuit breaker provides overload and short-circuit protection for industrial electrical systems. Designed for fixed installation, it offers four-pole protection and operates with a thermomagnetic trip mechanism suited to mixed fault profiles. It is suitable for use in three-phase and DC distribution arrangements where compact, panel-mounted protection is required.

Features and Benefits:


• 125A rating delivers steady continuous current handling • Thermomagnetic tripping offers combined thermal and magnetic protection • 4kA breaking capacity limits fault energy during short circuits • Rated to 690V AC and 500V DC supports AC and DC networks • Screw terminals ensure secure conductor connections

Applications


• Suitable for motor control panels requiring overcurrent protection • Ideal for distribution boards in industrial automation systems • Used for protection of DC-powered control circuits and battery systems • Can be used in electrical switchgear for manufacturing plants

How is it mounted within an electrical enclosure?


It installs as a fixed-mount device designed for secure panel attachment and stable connection in Compact enclosures.

What Terminal connection method does it use for conductors?


It employs screw-type terminals that provide mechanical retention and electrical contact for a range of cable sizes.

Which standards govern its Basic performance?


It complies with IEC specifications for circuit-breaking performance and safety characteristics.

How does the trip mechanism respond to different fault types?


The thermomagnetic arrangement provides time-delayed response to overloads via the thermal element and instantaneous interruption of high-magnitude faults via the magnetic element.

관련된 링크들