Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 300 A, Breaking Capacity 3 kA, Fixed
- RS 제품 번호:
- 231-304
- 제조사 부품 번호:
- 107519 NZMC2-A300
- 제조업체:
- Eaton
Subtotal (1 unit)*
₩2,748,691.60
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량 | 한팩당 |
|---|---|
| 1 + | ₩2,748,691.60 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 231-304
- 제조사 부품 번호:
- 107519 NZMC2-A300
- 제조업체:
- Eaton
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Eaton | |
| Product Type | Molded Case Circuit Breaker | |
| Range | NZM | |
| Series | NZM | |
| Number of Poles | 3 | |
| Current Rating | 300 A | |
| Breaking Capacity | 3kA | |
| Mount Type | Fixed | |
| Terminal Type | Screw | |
| Width | 105 mm | |
| Standards/Approvals | IEC/EN 60947, RoHS | |
| Depth | 149mm | |
| Height | 184mm | |
| Break Time | 10 ms | |
| 모두 선택 | ||
|---|---|---|
브랜드 Eaton | ||
Product Type Molded Case Circuit Breaker | ||
Range NZM | ||
Series NZM | ||
Number of Poles 3 | ||
Current Rating 300 A | ||
Breaking Capacity 3kA | ||
Mount Type Fixed | ||
Terminal Type Screw | ||
Width 105 mm | ||
Standards/Approvals IEC/EN 60947, RoHS | ||
Depth 149mm | ||
Height 184mm | ||
Break Time 10 ms | ||
- COO (Country of Origin):
- RO
The Eaton Molded Case Circuit Breaker moulded case circuit breaker is engineered for superior performance in a variety of applications. This advanced circuit breaker provides robust protection against overloads and short circuits, designed to ensure reliability in critical supply systems. With a maximum current rating of 300 A and a voltage capacity of up to 690 V, this device meets the demands of modern electrical installations. Its thermomagnetic release system enhances operational safety, allowing for quick response during fault conditions. Combining cutting-edge technology with an enduring build, the NZM series is the ideal solution for environments requiring exceptional electrical performance and compliance with international standards.
Employs a thermomagnetic release for reliable fault clearance
Designed for seamless installation onto DIN rail systems
Constructed to meet stringent electromagnetic compatibility requirements
Displays a degree of protection rated IP40 safeguarding internal components
Supports environmental adaptability with damp heat resistance
관련된 링크들
- Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 300 A, Breaking Capacity 3 kA, Fixed
- Eaton, NZM, NZM Molded Case Circuit Breaker 4-Pole 300 A, Breaking Capacity 3 kA, Fixed
- Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 250 A, Breaking Capacity 36 kA, Fixed
- Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 500 A, Breaking Capacity 4 kA, Fixed
- Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 320 A, Breaking Capacity 4 kA, Fixed
- Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 400 A, Breaking Capacity 4 kA, Fixed
- Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 250 A, Breaking Capacity 4 kA, Fixed
- Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 200 A, Breaking Capacity 4 kA, Fixed